The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Impaired left ventricular diastolic filling in patients with coronary artery disease: assessment with radionuclide angiography.
Abstract
To assess left ventricular (LV) diastolic filling at rest in patients with coronary artery disease (CAD), we analyzed high-resolution time-activity curves (10-20 msec/frame) obtained from gated radionuclide angiograms in 231 patients. Peak LV filling rate (PFR), expressed in end-diastolic volumes per second (EDV/sec), was subnormal in CAD patients (1.8 +/- 0.6 [+/- SD] vs normal mean of 3.3 +/- 0.6, p les than 0.001) and time to PFR (TPFR), measured from end-systole to PFR, was prolonged (171 +/- 41 msec vs normal mean of 136 +/- 23 msec, p less than 0.001). These indexes were also abnormal in the 141 patients with normal resting LV ejection fraction (PFR = 2.1 +/- 0.5 EDV/sec; TPFR = 175 +/- 36 msec) and in 123 patients without Q waves on the ECG (PFR = 2.1 +/- 0.5 EDV/sec; TPFR = 168 +/- 38 msec). Abnormal LV filling at rest (PFR less than 2.5 EDV/sec or TPFR greater than 180 msec) was found in 91% of all patients with CAD, 86% of patients with normal resting LV ejection fractions, 85% of patients without Q waves, and 82% of patients with normal resting LV ejection fraction, no resting regional wall motion abnormalities and no Q waves. Thus, LV diastolic filling, evaluated noninvasively by radionuclide angiography, is abnormal in a high percentage of patients with CAD at rest independent of LV systolic function or previous myocardial infarction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An analysis of variance test for normality (complete samples)
SHAPIRO, S. S., & WILK, M. B. (1965) · Biometrika · doi:10.1093/biomet/52.3-4.591 · Cited by 23,480
Cited by
Structural features of the athlete heart as defined by echocardiography
Maron, B. J. (1986) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(86)80282-0 · Cited by 516
Oki, T., Tabata, T., Yamada, H., Wakatsuki, T., Shinohara, H., Nishikado, A., Iuchi, A., Fukuda, N., & Ito, S. (1997) · The American Journal of Cardiology · doi:10.1016/s0002-9149(97)00015-5 · Cited by 486
Metadata
- Authors
- Bonow, R. O., Bacharach, S. L., Green, M. V., Kent, K. M., Rosing, D. R., Lipson, L. C., Leon, M. B., & Epstein, S. E.
- Venue
- Circulation
- Published
- 1981-08
- Volume
- 64
- Issue
- 2
- Pages
- 315-323
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2050630499
- Cited by
- 573
- References
- 1
- FWCI
- 13.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Impaired left ventricular diastolic filling in patients with coronary artery disease: assessment with radionuclide angiography. https://app.cochat.ai/papers/10.1161/01.cir.64.2.315
- The paper
- Bonow, R. O., Bacharach, S. L., Green, M. V., Kent, K. M., Rosing, D. R., Lipson, L. C., Leon, M. B., & Epstein, S. E. (1981). Impaired left ventricular diastolic filling in patients with coronary artery disease: assessment with radionuclide angiography. Circulation. https://doi.org/10.1161/01.cir.64.2.315
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).