The DOI matches its Crossref record.
Reat-time inferior vena caval ultrasonography: normal and abnormal findings and its use in assessing right-heart function.
Abstract
We studied the inferior vena cava (IVC) as an index of right-heart function in 111 patients. A two-dimensional echocardiographic sector was used to visualize the IVC, and its M-mode cursor was used to generate a time-motion record of the IVC size and pulsation. Normal subjects had a small presystolic A wave (less than 125% of the end-diastolic IVC dimension), a small systolic V wave (less than 140% of the end-diastolic IVC dimension), and a 50% inspiratory decrease in IVC dimension. The A wave was absent in patients with atrial fibrillation. When normalized for body surface area, mean end-diastolic IVC dimension correlated with mean right atrial pressure (r = 0.72, p less than 0.001). An A wave greater than or equal to 125% of end-diastolic IVC dimension was recorded in 71% of patients with sinus rhythm and an elevated right ventricular end-diastolic pressure of 10 mm Hg or greater, but in no patient with right ventricular end-diastolic pressure of less than 10 mm Hg (p less than 0.001). A V wave greater than or equal to 140% of end-diastolic IVC dimension was recorded in 75% of patients with severe tricuspid insufficiency, but in no patient with mild or no tricuspid insufficiency (p less than 0.001). The inspiratory decrease in IVC dimension correlated with radionuclide right ventricular ejection fraction (r = 0.75, p less than 0.001); no respiratory variation in end-diastolic IVC dimension occurred in patients with significant right ventricular dysfunction (right ventricular ejection less than 25%) or in patients with constrictive pericarditis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Marik, P. E., Cavallazzi, R., Vasu, T., & Hirani, A. (2009) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181a590da · Cited by 1,272
Kircher, B. J., Himelman, R. B., & Schiller, N. B. (1990) · The American Journal of Cardiology · doi:10.1016/0002-9149(90)90711-9 · Cited by 1,027
Reappraisal of the Use of Inferior Vena Cava for Estimating Right Atrial Pressure
Brennan, J. M., Blair, J. E., Goonewardena, S., Ronan, A., Shah, D., Vasaiwala, S., Kirkpatrick, J. N., & Spencer, K. T. (2007) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2007.01.005 · Cited by 459
Moreno, F. L. L., Hagan, A. D., Holmen, J. R., Pryor, T. A., Strickland, R. D., & Castle, C. H. (1984) · The American Journal of Cardiology · doi:10.1016/0002-9149(84)90034-1 · Cited by 308
The response of the vena cava to abdominal breathing
Byeon, K., Choi, J.-O., Yang, J. H., Sung, J., Park, S. W., Oh, J. K., & Hong, K. P. (2012) · The Journal of Alternative and Complementary Medicine · doi:10.1089/acm.2010.0656 · Cited by 42
Metadata
- Authors
- Mintz, G. S., Kotler, M. N., Parry, W. R., Iskandrian, A. S., & Kane, S. A.
- Venue
- Circulation
- Published
- 1981-11
- Volume
- 64
- Issue
- 5
- Pages
- 1018-1025
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W1972770801
- Cited by
- 181
- References
- 0
- FWCI
- 3.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reat-time inferior vena caval ultrasonography: normal and abnormal findings and its use in assessing right-heart function. https://app.cochat.ai/papers/10.1161/01.cir.64.5.1018
- The paper
- Mintz, G. S., Kotler, M. N., Parry, W. R., Iskandrian, A. S., & Kane, S. A. (1981). Reat-time inferior vena caval ultrasonography: normal and abnormal findings and its use in assessing right-heart function. Circulation. https://doi.org/10.1161/01.cir.64.5.1018
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.