The sinus node electrogram in patients with and without sick sinus syndrome: techniques and correlation between directly measured and indirectly estimated sinoatrial conduction time.
Open accessThe DOI matches its Crossref record.
Abstract
Sinus node electrograms (SNEs) were recorded in 44 patients using a standard quadripolar electrode catheter (USCI #6) with 10-mm interelectrode distance.In 23 patients, the catheter was posi- tioned at the junction of the superior vena cava (SVC) and right atrial (RA) wall so that the concave curve of the catheter was facing the concave surface of the RA wall.The distal poles of the catheter were close to but not in direct contact with the RA endocardium underlying the anatomic location of the sinus node (method 1).In 21 patients, the catheter was looped in the RA and advanced to the junction of the SVC-RA wall so that the distal poles of the catheter were in direct contact with the RA endocardium underlying the area of the sinus node (method 2).Stable SNEs could be obtained in 10 of 23 patients (43%) by method 1 and in 18 of 21 (86%) by method 2. SNEs by both methods showed two negatively directed deflections (diastolic and upstroke slope of the sinus node) of low frequency and amplitude occurring after the deflections of the T and U waves but before the P wave and intraatrial electrograms from various atrial sites.Unlike method 1, atrial activation by method 2 was characterized by an atrial injury potential.SNEs by method 2 were more stable and less prone to baseline drifts.Carotid sinus massage performed in 10 patients resulted in prolongation of the onset of the upstroke slope to atrial activation.In one patient, it resulted in marked first-degree sinoatrial block.SNEs were recorded in one patient during and after a run of spontaneous atrial flutter.After termination of atrial flutter, sinoatrial conduction time (SACT) prolonged for the first postflutter sinus beat and normalized by the third sinus beat.Direct SACTwas assessed on the SNE in all 28 patients, 12 of whom had sick sinus syndrome (SSS).SACT was also estimated indirectly by continuous pacing in 28 patients and by premature stimulation in 20 patients.Direct SACT was significantly (p < 0.001) longer in patients with SSS (135 30 msec, mean SD) than in patients without SSS ( 8712 msec).There was a good correlation between direct SACT and SACT by continuous pacing (r = 0.843, n = 28) and direct SACT and SACT by premature stimulation (r = 0.778, n = 18).However, in certain patients, there were appreciable differences and direct SACTwas longer than estimated SACT by continuous pacing or premature stimulation.We conclude that (1) the success rate of stable SNEs with no appreciable baseline drift is increased with direct contact of the catheter with atrial endocardium underlying the sinus node area (method 2); (2) carotid sinus massage results in depression of sinus node automaticity and prolongation of SACT; (3) direct SACT is significantly longer in patients with SSS and can separate most patients with from those without SSS; and (4) there is a good correlation between direct SACT and indirectly estimated SACT, although the latter underestimates the actual SACT.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Kusumoto, F. M., Schoenfeld, M. H., Barrett, C., Edgerton, J. R., Ellenbogen, K. A., Gold, M. R., Goldschlager, N. F., Hamilton, R. M., Joglar, J. A., Kim, R. J., et al. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.10.044 · Cited by 1,008
The sinoatrial node, a heterogeneous pacemaker structure
Boyett, M. (2000) · Cardiovascular Research · doi:10.1016/s0008-6363(00)00135-8 · Cited by 698
Kusumoto, F. M., Schoenfeld, M. H., Barrett, C., Edgerton, J. R., Ellenbogen, K. A., Gold, M. R., Goldschlager, N. F., Hamilton, R. M., Joglar, J. A., Kim, R. J., et al. (2019) · Circulation · doi:10.1161/cir.0000000000000628 · Cited by 603
Guidelines for clinical intracardiac electrophysiological and catheter ablation procedures
Zipes, D. P., Dimarco, J. P., Gillette, P. C., Jackman, W. M., Myerburg, R. J., Rahimtoola, S. H., Ritchie, J. L., Cheitlin, M. D., Garson, A., Gibbons, R. J., et al. (1995) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(95)80037-h · Cited by 282
Kusumoto, F. M., Schoenfeld, M. H., Barrett, C., Edgerton, J. R., Ellenbogen, K. A., Gold, M. R., Goldschlager, N. F., Hamilton, R. M., Joglar, J. A., Kim, R. J., et al. (2019) · Heart Rhythm · doi:10.1016/j.hrthm.2018.10.037 · Cited by 131
Metadata
- Authors
- Gomes, J. A., Kang, P. S., & El-Sherif, N.
- Venue
- Circulation
- Published
- 1982-10
- Volume
- 66
- Issue
- 4
- Pages
- 864-873
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2028358805
- Cited by
- 77
- References
- 0
- FWCI
- 5.86
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The sinus node electrogram in patients with and without sick sinus syndrome: techniques and correlation between directly measured and indirectly estimated sinoatrial conduction time. https://app.cochat.ai/papers/10.1161/01.cir.66.4.864
- The paper
- Gomes, J. A., Kang, P. S., & El-Sherif, N. (1982). The sinus node electrogram in patients with and without sick sinus syndrome: techniques and correlation between directly measured and indirectly estimated sinoatrial conduction time. Circulation. https://doi.org/10.1161/01.cir.66.4.864
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.