Cited by 289Heart Failure Treatment and ManagementCardiovascular and exercise physiologyHeart rate and cardiovascular health

Improved exercise capacity and differing arterial and venous tolerance during chronic isosorbide dinitrate therapy for congestive heart failure.

Leier, C V, Huss, P, Magorien, R D, Unverferth, D V·1983·Circulation

Abstract

We studied 30 patients with moderate-to-severe congestive heart failure in a double-blind, randomized, placebo-controlled trial to determine the acute and long-term effects of isosorbide dinitrate on clinical status and on resting and exercise hemodynamics. Seventeen patients received placebo and 13 isosorbide dinitrate. First-dose isosorbide dinitrate (40 mg orally) decreased resting and exercise pulmonary capillary wedge pressure, pulmonic and systemic arterial pressures and pulmonic and systemic vascular resistances without augmenting exercise capacity. Compared with placebo, chronic therapy with isosorbide dinitrate (40 mg orally every 6 hours for 12 weeks) significantly improved clinical status and exercise capacity. Resting and exercise systemic blood pressure and systemic vascular resistance returned to baseline values during chronic isosorbide dinitrate therapy, but pulmonary capillary wedge pressure, pulmonary artery pressure and pulmonary vascular resistance remained improved. In patients with congestive heart failure, 12 weeks of oral isosorbide dinitrate therapy improves resting and exercise hemodynamics, exercise capacity, and clinical status; tolerance develops to the systemic arterial vascular effects without attenuation of the venous and pulmonary vascular effects.

Integrity signals

Registry

Crossref · 10.1161/01.cir.67.4.817

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

The citation lists haven’t been fetched yet

References 14 · Cited by 289

Authors
Leier, C. V., Huss, P., Magorien, R. D., & Unverferth, D. V.
Venue
Circulation
Published
1983-04
Volume
67
Issue
4
Pages
817-822
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2001535795
Cited by
289
References
14
Citations by year
2025: 1 · 2024: 1 · 2022: 1 · 2021: 1 · 2020: 1 · 2018: 2 · 2017: 1 · 2016: 1 · 2015: 6 · 2014: 2 · 2013: 2 · 2012: 1
FWCI
21.56
Type
journal article
Language
en
Open access
closed
Locations
  • Circulation (publishedVersion)
  • PubMed (publishedVersion)
Funders
Ohio State University
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Failure Treatment and Management
  • Health Sciences › Medicine › Complementary and alternative medicine › Cardiovascular and exercise physiology
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart rate and cardiovascular health
Keywords
isosorbide dinitrate, congestive heart failure, exercise capacity, hemodynamics, pulmonary capillary wedge pressure, pulmonary vascular resistance, systemic vascular resistance, nitrate, clinical status
MeSH terms
Blood Pressure, Clinical Trials as Topic, Double-Blind Method, Echocardiography, Physical Exertion, Female, Heart Failure, Humans, Isosorbide Dinitrate, Male, Middle Aged, Pulmonary Artery, Pulmonary Wedge Pressure, Systole, Vascular Resistance

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review