Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 747

The DOI matches its Crossref record.

Characteristics and possible mechanism of ventricular arrhythmia dependent on the dispersion of action potential durations.

Open access
Kuo, C S, Munakata, K, Reddy, C P, Surawicz, B·1983·Circulation

Abstract

The arrhythmogenic role of increased dispersion of repolarization (dispersion) was studied in 23 open-chest dogs using six simultaneously recorded monophasic action potentials (MAPs) from the ventricular surface and programmed ventricular premature stimulation (VPS). Increased dispersion was induced by generalized hypothermia (29 degrees C) and regional warm blood (38-43 degrees C) perfusion through a coronary artery branch. Hypothermia and regional warm blood perfusion increased maximum dispersion from 13 +/- 10 to 111 +/- 16 msec (p less than 0.001), predominantly because of the increased MAP duration difference (10 +/- 15 vs 97 +/- 16 msec, p less than 0.001). The maximal difference between activation times was not significantly changed, but the QRS duration increased from 47 +/- 6 to 52 +/- 7 msec (p less than 0.01). Ventricular arrhythmia did not occur spontaneously but was induced by a single VPS in all 23 dogs during hypothermia and regional warm blood perfusion when dispersion reached a critical magnitude. The critical magnitude of dispersion required to induce ventricular arrhythmia was documented in 16 dogs by stepwise increments or decrements of dispersion. In four dogs, an increase in atrial pacing rate of 24 beats/min prevented induction of ventricular arrhythmia by decreasing dispersion from a critical magnitude of 103 +/- 5 msec to a nonarrhythmogenic value of 86 +/- 9 msec (p less than 0.05). In six dogs, we compared the stimulation site-dependent effects of VPS applied in the region with short and long MAPs. In all dogs, ventricular arrhythmia was inducible only by VPS from the region with a short MAP. Premature impulses from this region propagated more slowly than those from the region with a long MAP. Our results show that the large dispersion of repolarization facilitates the development of a conduction delay necessary to induce sustained arrhythmia by an early premature stimulus applied at the site with a short MAP.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.67.6.1356

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 747

Metadata

Authors
Kuo, C. S., Munakata, K., Reddy, C. P., & Surawicz, B.
Venue
Circulation
Published
1983-06
Volume
67
Issue
6
Pages
1356-1367
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2044097193
Cited by
747
References
0
FWCI
9.81
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Characteristics and possible mechanism of ventricular arrhythmia dependent on the dispersion of action potential durations. https://app.cochat.ai/papers/10.1161/01.cir.67.6.1356
The paper
Kuo, C. S., Munakata, K., Reddy, C. P., & Surawicz, B. (1983). Characteristics and possible mechanism of ventricular arrhythmia dependent on the dispersion of action potential durations. Circulation. https://doi.org/10.1161/01.cir.67.6.1356

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.