Determination of anaerobic threshold for assessment of functional state in patients with chronic heart failure.

Matsumura, N, Nishijima, H, Kojima, S, Hashimoto, F, Minami, M, Yasuda, H·1983·Circulation

Abstract

The use of anaerobic threshold in assessment of aerobic capacity was evaluated in 34 normal subjects and 47 patients with various kinds of chronic heart disease. Anaerobic threshold was determined as the oxygen consumption (VO2) at which a linear relationship between pulmonary ventilation (VE) and VO2 was lost during progressive treadmill exercise. Anaerobic threshold determined in this manner was validated with that determined by blood lactate measurements in eight normal subjects and nine cardiac patients (r = .962, p less than .001). Thereafter, anaerobic threshold was determined only by respiratory measurements. In symptom-limited, maximal exercise, anaerobic threshold was reached well before maximal effort and corresponded to 70% of maximal VO2 both in normal subjects and cardiac patients. Anaerobic threshold decreased as age progressed in normal subjects (r = - .70, p less than .001). Anaerobic threshold in cardiac patients was lower than that in the normal subjects and decreased progressively as New York Heart Association functional classification advanced (normal, 32.95 +/- 6.17 ml/min/kg; class I, 22.78 +/- 3.74; class II, 16.99 +/- 3.66; class III, 12.97 +/- 2.76; p less than .01 between each group other than between class II and class III). Anaerobic threshold in cardiac patients correlated poorly with other objective indices, e.g., cardiomegaly (r = -.54, p less than .001) and rise in pulmonary wedge pressure (r = -.64, p less than .001). At anaerobic threshold, cardiac patients subjectively graded the work load as light (13%), light-to-moderate (27%), moderate (30%), and moderate-to-heavy (28%). Thus determination of anaerobic threshold by respiratory measurements is a safe, accurate, and objective method to measure aerobic capacity in cardiac patients and in normal subjects.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.68.2.360

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 189

Metadata

Authors
Matsumura, N., Nishijima, H., Kojima, S., Hashimoto, F., Minami, M., & Yasuda, H.
Venue
Circulation
Published
1983-08
Volume
68
Issue
2
Pages
360-367
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W1990596055
Cited by
189
References
1
FWCI
19.15
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Determination of anaerobic threshold for assessment of functional state in patients with chronic heart failure. https://app.cochat.ai/papers/10.1161/01.cir.68.2.360
The paper
Matsumura, N., Nishijima, H., Kojima, S., Hashimoto, F., Minami, M., & Yasuda, H. (1983). Determination of anaerobic threshold for assessment of functional state in patients with chronic heart failure. Circulation. https://doi.org/10.1161/01.cir.68.2.360

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.