The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
The relationships among ventricular arrhythmias, left ventricular dysfunction, and mortality in the 2 years after myocardial infarction.
Abstract
We examined the relationships among ventricular arrhythmias, left ventricular dysfunction, and mortality after the occurrence of myocardial infarction in 766 patients who enrolled in a nine-hospital study and underwent two special tests. Frequency and repetitiveness of ventricular premature depolarizations (VPDs) were determined by computer analysis of predischarge 24 hr electrocardiographic recordings. The left ventricular ejection fraction (LVEF) was determined by radionuclide ventriculography and dichotomized at its optimal value of 30%. Frequency of VPDs was divided into three categories: (1) less than one per hour, (2) one to 2.9 per hour, and (3) three or more per hour. Repetitiveness of VPDs was also divided into three categories: (1) no repetitive VPDs, (2) paired VPDs, and (3) VPD runs. These variables were related, one at a time and jointly, to total mortality and to deaths caused by arrhythmias. The hazard ratios for dying in the higher or highest risk stratum vs the lower or lowest stratum for each variable (adjusted for the effects of the others) were: LVEF below 30%, 3.5; VPD runs, 1.9; and VPD frequency of three or more per hour, 2.0. There were no significant interactions among the three variables with respect to effects on the risk of mortality. There was a suggestion of an interaction between each risk variable and time after infarction. LVEF below 30% was a better predictor of early mortality (less than 6 months) and the presence of ventricular arrhythmias was a better predictor of late mortality (after 6 months).(ABSTRACT TRUNCATED AT 250 WORDS)
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Statistical Methods for Rates and Proportions
Fleiss, J. L., Levin, B., & Paik, M. C. (2003) · Wiley Series in Probability and Statistics · doi:10.1002/0471445428 · Cited by 18,646
Self-citation
Cited by
Moss, A. J., Hall, W. J., Cannom, D. S., Daubert, J. P., Higgins, S. L., Klein, H., Levine, J. H., Saksena, S., Waldo, A. L., Wilber, D., et al. (1996) · New England Journal of Medicine · doi:10.1056/nejm199612263352601 · Cited by 4,165
Kleiger, R. E., Miller, J. P., Bigger, J. T., & Moss, A. J. (1987) · The American Journal of Cardiology · doi:10.1016/0002-9149(87)90795-8 · Cited by 3,995
Self-citationProphylactic use of an implantable cardioverter-defibrillator after acute myocardial infarction
Hohnloser, S. H., Kuck, K. H., Dorian, P., Roberts, R. S., Hampton, J. R., Hatala, R., Fain, E., Gent, M., & Connolly, S. J. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa041489 · Cited by 1,519
Goldberger, J. J., Cain, M. E., Hohnloser, S. H., Kadish, A. H., Knight, B. P., Lauer, M. S., Maron, B. J., Page, R. L., Passman, R. S., Siscovick, D., et al. (2008) · Circulation · doi:10.1161/circulationaha.107.189375 · Cited by 1,450
Wearable Sensors for Remote Health Monitoring
Majumder, S., Mondal, T., & Deen, M. (2017) · Sensors · doi:10.3390/s17010130 · Cited by 1,375
Metadata
- Authors
- Bigger, J. T., Fleiss, J. L., Kleiger, R., Miller, J. P., & Rolnitzky, L. M.
- Venue
- Circulation
- Published
- 1984-02
- Volume
- 69
- Issue
- 2
- Pages
- 250-258
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2094892482
- Cited by
- 1,286
- References
- 1
- FWCI
- 35.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The relationships among ventricular arrhythmias, left ventricular dysfunction, and mortality in the 2 years after myocardial infarction. https://app.cochat.ai/papers/10.1161/01.cir.69.2.250
- The paper
- Bigger, J. T., Fleiss, J. L., Kleiger, R., Miller, J. P., & Rolnitzky, L. M. (1984). The relationships among ventricular arrhythmias, left ventricular dysfunction, and mortality in the 2 years after myocardial infarction. Circulation. https://doi.org/10.1161/01.cir.69.2.250
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.