The DOI matches its Crossref record.
Reflex constriction of significant coronary stenosis as a mechanism contributing to ischemic left ventricular dysfunction during isometric exercise.
Open accessAbstract
To study the mechanisms of myocardial ischemia during isometric exercise, handgrip was sustained, for 4.5 min at 25% of maximum by 11 patients with at least one significant coronary stenosis each, during cardiac catheterization. After recovery, the handgrip that was repeated with simultaneous infusion of nitroglycerin (50 micrograms over 4 min) directly into the diseased vessel. The cardiovascular response was assessed by hemodynamic and by computer-assisted measurements of stenosis. During the first handgrip test pulmonary capillary wedge pressure rose 56% (15 to 23 mm Hg; p less than .001), the heart rate-systolic pressure product rose 33% (p less than .01), and the diseased epicardial arteries constricted. Luminal area in the stenotic segment was reduced by 35% (p less than .01), resulting in a 243% increase in estimated stenotic flow resistance (30 to 103 mm Hg/ml/sec; p less than .001). During handgrip with intracoronary nitroglycerin, the pressure-rate product again increased 33%, but relative to resting control, capillary wedge pressure fell 4 mm Hg in association with a 32% increase in luminal area of the stenosis and a 28% reduction in flow resistance (all significantly different from the response to handgrip alone: p less than .001, .01, and .005, respectively). Thus, coronary vasoconstriction, not increased pressure-rate product, is the dominant mechanism for ischemic left ventricular dysfunction during isometric exercise in patients with significant coronary stenoses.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Cocaine-Induced Coronary-Artery Vasoconstriction
Lange, R. A., Cigarroa, R. G., Yancy, C. W., Willard, J. E., Popma, J. J., Sills, M. N., McBride, W., Kim, A. S., & Hillis, L. D. (1989) · New England Journal of Medicine · doi:10.1056/nejm198912073212301 · Cited by 619
Metadata
- Authors
- Brown, B. G., Lee, A. B., Bolson, E. L., & Dodge, H. T.
- Venue
- Circulation
- Published
- 1984-07
- Volume
- 70
- Issue
- 1
- Pages
- 18-24
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2049326571
- Cited by
- 240
- References
- 0
- FWCI
- 15.99
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reflex constriction of significant coronary stenosis as a mechanism contributing to ischemic left ventricular dysfunction during isometric exercise. https://app.cochat.ai/papers/10.1161/01.cir.70.1.18
- The paper
- Brown, B. G., Lee, A. B., Bolson, E. L., & Dodge, H. T. (1984). Reflex constriction of significant coronary stenosis as a mechanism contributing to ischemic left ventricular dysfunction during isometric exercise. Circulation. https://doi.org/10.1161/01.cir.70.1.18
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.