Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 452

The DOI matches its Crossref record.

Clinical experience, complications, and survival in 70 patients with the automatic implantable cardioverter/defibrillator.

Echt, D S, Armstrong, K, Schmidt, P, Oyer, P E, Stinson, E B, Winkle, R A·1985·Circulation

Abstract

Seventy patients received the automatic implantable defibrillator, five original devices and 72 modified second-generation devices using only bipolar rate sensing and delivering an R wave synchronous cardioverting/defibrillating shock, for either ventricular tachycardia or fibrillation. The primary clinical arrhythmia was sustained ventricular tachycardia in 32 patients, ventricular fibrillation in 20 patients, and both ventricular tachycardia and fibrillation in 18 patients. Before implantation of the device the patients had survived 3.1 +/- 2.3 arrhythmic episodes, including 1.9 +/- 1.7 cardiac arrest, and had received 4.0 +/- 2.1 antiarrhythmic drugs without improvement. Sixty-eight patients ultimately received devices. After a follow-up period of 8.9 +/- 7.7 months (range 1 to 33), 37 patients received a total of 463 discharges. Inability to determine the precise reason for most discharges and the unpleasant nature of the discharges were the major clinical problems encountered. Complications included postoperative death (one patient), lead problems (six patients), inadequate energy requiring explanation (two patients), and pocket infection (one patient. Life-table analysis revealed 6 and 12 month cardiovascular survival of 95.0% and 89.9% and sudden death survival of 98.2%. In our experience, survival with the automatic implantable cardioverter/defibrillator exceeds that with other forms of therapy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.71.2.289

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 452

Metadata

Authors
Echt, D. S., Armstrong, K., Schmidt, P., Oyer, P. E., Stinson, E. B., & Winkle, R. A.
Venue
Circulation
Published
1985-02
Volume
71
Issue
2
Pages
289-296
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2041800048
Cited by
452
References
0
FWCI
30.86
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Clinical experience, complications, and survival in 70 patients with the automatic implantable cardioverter/defibrillator. https://app.cochat.ai/papers/10.1161/01.cir.71.2.289
The paper
Echt, D. S., Armstrong, K., Schmidt, P., Oyer, P. E., Stinson, E. B., & Winkle, R. A. (1985). Clinical experience, complications, and survival in 70 patients with the automatic implantable cardioverter/defibrillator. Circulation. https://doi.org/10.1161/01.cir.71.2.289

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.