Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 296

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Pulmonary venous flow pattern--its relationship to cardiac dynamics. A pulsed Doppler echocardiographic study.

Open access
Keren, G, Sherez, J, Megidish, R, Levitt, B, Laniado, S·1985·Circulation

Abstract

We studied the physiology of pulmonary venous flow in 13 normal subjects and five patients with atrial rhythm disorders and atrioventricular conduction disturbances with pulsed Doppler and two-dimensional echocardiography. The left atrium, mitral valve, and pulmonary venous ostia were visualized through the apical four-chamber view. Mitral and pulmonary venous flows were obtained by placing the Doppler sample volume at the appropriate orifice. Pulmonary venous flow was biphasic: a rapid filling wave was observed during systole when the mitral valve was closed; a second wave was observed in diastole during the rapid ventricular filling phase of mitral flow, but was significantly delayed. In patients without atrial contraction (atrial fibrillation and sinoatrial standstill), the initial rapid filling was greatly diminished and only the second diastolic wave appeared to contribute to left atrial filling. In patients with high-grade atrioventricular block, each atrial contraction was followed by a surge in flow from the pulmonary veins. These results are consistent with data obtained from invasive measurements in both dogs and man, and confirm the validity of the use of pulsed Doppler echocardiography in the study of pulmonary venous flow. We suggest that pulmonary venous flow is influenced by dynamic changes in left atrial pressure created by contraction and relaxation of the atrium and ventricle. The initial peak in pulmonary venous flow occurs with atrial relaxation simultaneously with the reduction of left atrial pressure, and the second peak occurs with left ventricular relaxation and rapid transmitral filling of the ventricle.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.71.6.1105

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 296

Metadata

Authors
Keren, G., Sherez, J., Megidish, R., Levitt, B., & Laniado, S.
Venue
Circulation
Published
1985-06
Volume
71
Issue
6
Pages
1105-1112
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2042299712
Cited by
296
References
2
FWCI
4.09
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Pulmonary venous flow pattern--its relationship to cardiac dynamics. A pulsed Doppler echocardiographic study. https://app.cochat.ai/papers/10.1161/01.cir.71.6.1105
The paper
Keren, G., Sherez, J., Megidish, R., Levitt, B., & Laniado, S. (1985). Pulmonary venous flow pattern--its relationship to cardiac dynamics. A pulsed Doppler echocardiographic study. Circulation. https://doi.org/10.1161/01.cir.71.6.1105

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.