Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 520

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Continuous-wave Doppler echocardiographic assessment of severity of calcific aortic stenosis: a simultaneous Doppler-catheter correlative study in 100 adult patients.

Open access
Currie, P J, Seward, J B, Reeder, G S, Vlietstra, R E, Bresnahan, D R, Bresnahan, J F, Smith, H C, Hagler, D J, Tajik, A J·1985·Circulation

Abstract

Studies of the correlation of aortic valve gradient determined by continuous-wave Doppler echocardiography and that determined at catheterization have, to date, involved young patients and nonsimultaneous measurements. We therefore obtained simultaneous Doppler echocardiographic and catheter measurements of pressure gradient in 100 consecutive adults (mean age 69, range 50 to 89 years). In 63 patients pressure measurements were obtained with dual-catheter techniques and in 37 they were obtained by withdrawal of the catheter from the left ventricle to the ascending aorta. Forty-six of these patients also underwent an outpatient Doppler study 7 days or less before catheterization. The simultaneous pressure waveforms and Doppler spectral velocity profiles were digitized at 10 msec intervals and maximum, mean, and instantaneous gradients (mm Hg) were derived for each. The correlation between the Doppler-determined gradient and the simultaneously measured maximum catheter gradient was r = .92 (SEE = 15 mm Hg), that between the Doppler-determined and mean catheter gradient was r = .93 (SEE = 10 mm Hg), and that between the Doppler and peak-to-peak catheter gradient was r = .91 (SEE = 14). The correlation between the nonsimultaneously Doppler-determined gradient and the maximum gradient measured by catheter was not as strong (r = .79, SEE = 24). The continuous-wave Doppler echocardiographic velocity profile represents the instantaneous transaortic pressure gradient throughout the cardiac cycle. The best correlation with continuous-wave Doppler-determined gradient was obtained with maximum and mean gradients measured by catheter. Continuous-wave Doppler echocardiography can be used to reliably predict the pressure gradient in adults with calcific aortic stenosis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.71.6.1162

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 520

Metadata

Authors
Currie, P. J., Seward, J. B., Reeder, G. S., Vlietstra, R. E., Bresnahan, D. R., Bresnahan, J. F., Smith, H. C., Hagler, D. J., & Tajik, A. J.
Venue
Circulation
Published
1985-06
Volume
71
Issue
6
Pages
1162-1169
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2014455026
Cited by
520
References
6
FWCI
28.02
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Continuous-wave Doppler echocardiographic assessment of severity of calcific aortic stenosis: a simultaneous Doppler-catheter correlative study in 100 adult patients. https://app.cochat.ai/papers/10.1161/01.cir.71.6.1162
The paper
Currie, P. J., Seward, J. B., Reeder, G. S., Vlietstra, R. E., Bresnahan, D. R., Bresnahan, J. F., Smith, H. C., Hagler, D. J., & Tajik, A. J. (1985). Continuous-wave Doppler echocardiographic assessment of severity of calcific aortic stenosis: a simultaneous Doppler-catheter correlative study in 100 adult patients. Circulation. https://doi.org/10.1161/01.cir.71.6.1162

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.