Efficacy and safety of transcatheter ablation of posteroseptal accessory pathways.
The DOI matches its Crossref record.
Abstract
Eight patients with a posteroseptal accessory pathway and symptomatic atrial fibrillation and/or orthodromic reciprocating tachycardia underwent attempted transcatheter ablation of the accessory pathway. A quadripolar electrode catheter was positioned within the coronary sinus such that the proximal pair of electrodes straddled the os. This proximal pair of electrodes was made electrically common and connected to the cathodal output of a defibrillator. A patch electrode placed over the midthoracic spine was connected to the anodal sink of the defibrillator. Two to three transcatheter shocks were delivered, with a cumulative energy of 600 to 900 J. Immediately after the shocks were delivered, retrograde accessory pathway conduction was absent in each patient. Anterograde conduction through the posteroseptal accessory pathway was absent in six patients. In one patient, retrograde accessory pathway conduction was absent and anterograde conduction was present but was slower than at baseline. In this patient, orthodromic tachycardia was no longer inducible and the ventricular rate during induced atrial fibrillation was 150 beats/min, compared with 220 beats/min before the attempted ablation. He has remained asymptomatic without antiarrhythmic drug therapy for 18 months. In one patient, the transcatheter shocks had no long-term effect on accessory pathway conduction. The shocks delivered at the os of the coronary sinus were well tolerated.(ABSTRACT TRUNCATED AT 250 WORDS)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Jackman, W. M., Wang, X., Friday, K. J., Roman, C. A., Moulton, K. P., Beckman, K. J., McClelland, J. H., Twidale, N., Hazlitt, H. A., Prior, M. I., et al. (1991) · New England Journal of Medicine · doi:10.1056/nejm199106063242301 · Cited by 1,422
High frequency alternating current ablation of an accessory pathway in humans
Borggrefe, M., Budde, T., Podczeck, A., & Breithardt, G. (1987) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(87)80200-0 · Cited by 285
KAY, G. N., EPSTEIN, A. E., DAILEY, S. M., & PLUMB, V. J. (1993) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.1993.tb01277.x · Cited by 192
Wong, J. B., Sonnenberg, F. A., Salem, D. N., & Pauker, S. G. (1990) · Annals of Internal Medicine · doi:10.7326/0003-4819-113-11-852 · Cited by 179
Effect of gender on postoperative outcomes and hospital stays after coronary artery bypass grafting
Aldea, G. S., Gaudiani, J. M., Shapira, O. M., Jacobs, A. K., Weinberg, J., Cupples, A. L., Lazar, H. L., & Shemin, R. J. (1999) · The Annals of Thoracic Surgery · doi:10.1016/s0003-4975(99)00055-7 · Cited by 172
MILSTEIN, S., SHARMA, A. D., GUIRAUDON, G. M., & KLEIN, G. J. (1987) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1987.tb04520.x · Cited by 166
Ectopic automatic atrial tachycardia in children: clinical characteristics, management and follow-up
Mehta, A. V., Sanchez, G. R., Sacks, E. J., Casta, A., Dunn, J. M., & Donner, R. M. (1988) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(88)90106-4 · Cited by 132
Metadata
- Authors
- Morady, F., Scheinman, M. M., Winston, S. A., DiCarlo, L. A., Davis, J. C., Griffin, J. C., Ruder, M., Abbott, J. A., & Eldar, M.
- Venue
- Circulation
- Published
- 1985-07
- Volume
- 72
- Issue
- 1
- Pages
- 170-177
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W1968214218
- Cited by
- 166
- References
- 0
- FWCI
- 17.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.