Intraoperative detection of myocardial ischemia in high-risk patients: electrocardiography versus two-dimensional transesophageal echocardiography.
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Because acute segmental wall motion abnormalities (SWMAs) of the left ventricle are highly sensitive and specific indicators of myocardial ischemia, this study compared the incidence and significance of ischemia, as detected by two-dimensional transesophageal echocardiography and surface electrocardiography, during anesthesia and surgery in patients at high risk of myocardial ischemia. During surgery, 24 of the 50 patients studied had new SWMAs, whereas only six had ST segment changes. All patients with ST segment changes also had new SWMAs: in three instances, SWMAs occurred before the ST segment change, and in three instances, they occurred simultaneously. All three patients who had intraoperative myocardial infarctions also had persistent intraoperative SWMAs, whereas only one patient had ST segment changes. Ten healthy patients requiring noncardiovascular surgery were monitored similarly; none of these had SWMAs, ST segment changes, or myocardial infarction. This study demonstrates the superiority of two-dimensional transesophageal echocardiography over electrocardiography for the intraoperative detection of myocardial ischemia. Furthermore, when new SWMAs persist to the conclusion of surgery, myocardial infarction is likely to have occurred.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
THE EFFECT OF CORONARY OCCLUSION ON MYOCARDIAL CONTRACTION
Tennant, R., & Wiggers, C. J. (1935) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1935.112.2.351 · Cited by 1,128
Mortality associated with anaesthesia
Lunn, J. N., & Mushin, W. W. (1982) · Anaesthesia · doi:10.1111/j.1365-2044.1982.tb01824.x · Cited by 326
Computer Analysis of Postanesthetic Deaths
Marx, G. F., Mateo, C. V., & Orkin, L. R. (1973) · Anesthesiology · doi:10.1097/00000542-197307000-00010 · Cited by 293
Waters, D. D., Luz, P. D., Wyatt, H. L., Swan, H. J. C., & Forrester, J. S. (1977) · The American Journal of Cardiology · doi:10.1016/s0002-9149(77)80163-x · Cited by 190
Schluter, M., Langenstein, B. A., Polster, J., Kremer, P., Souquet, J., Engel, S., & Hanrath, P. (1982) · Heart · doi:10.1136/hrt.48.1.67 · Cited by 168
Transesophageal two-dimensional echocardiography: Comparison of ultrasonic and anatomic sections
Schlüter, M., Hinrichs, A., Thier, W., Kremer, P., Schröder, S., Cahalan, M. K., & Hanrath, P. (1984) · The American Journal of Cardiology · doi:10.1016/0002-9149(84)90657-x · Cited by 124
Self-citationFascicular conduction disturbances after coronary bypass surgery
Zeldis, S. M., Morganroth, J., Horowitz, L. N., et al. (1978) · The American Journal of Cardiology · doi:10.1016/0002-9149(78)90725-7 · Cited by 53
Cited by
Shanewise, J. S., Cheung, A. T., Aronson, S., Stewart, W. J., Weiss, R. L., Mark, J. B., Savage, R. M., Sears-Rogan, P., Mathew, J. P., Quiñones, M. A., et al. (1999) · Journal of the American Society of Echocardiography · doi:10.1016/s0894-7317(99)70199-9 · Cited by 728
Self-citationSvensson, L. A. R. G., & Crawford, E. S. (1992) · Current Problems in Surgery · doi:10.1016/0011-3840(92)90003-l · Cited by 180
Thielmann, M., Sharma, V., Al-Attar, N., Bulluck, H., Bisleri, G., Bunge, J. J., Czerny, M., Ferdinandy, P., Frey, U. H., Heusch, G., et al. (2017) · European Heart Journal · doi:10.1093/eurheartj/ehx383 · Cited by 175
Muhiudeen, I. A., Roberson, D. A., Silverman, N. H., Haas, G., Turley, K., & Cahalan, M. K. (1990) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(90)90320-o · Cited by 100
Self-citation
Metadata
- Authors
- Smith, J. S., Cahalan, M. K., Benefiel, D. J., Byrd, B. F., Lurz, F. W., Shapiro, W. A., Roizen, M. F., Bouchard, A., & Schiller, N. B.
- Venue
- Circulation
- Published
- 1985-11
- Volume
- 72
- Issue
- 5
- Pages
- 1015-1021
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2028501269
- Cited by
- 456
- References
- 7
- FWCI
- 18.46
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Intraoperative detection of myocardial ischemia in high-risk patients: electrocardiography versus two-dimensional transesophageal echocardiography. https://app.cochat.ai/papers/10.1161/01.cir.72.5.1015
- The paper
- Smith, J. S., Cahalan, M. K., Benefiel, D. J., Byrd, B. F., Lurz, F. W., Shapiro, W. A., Roizen, M. F., Bouchard, A., & Schiller, N. B. (1985). Intraoperative detection of myocardial ischemia in high-risk patients: electrocardiography versus two-dimensional transesophageal echocardiography. Circulation. https://doi.org/10.1161/01.cir.72.5.1015
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.