Comparative accuracy of two-dimensional echocardiography and Doppler pressure half-time methods in assessing severity of mitral stenosis in patients with and without prior commissurotomy.
The DOI matches its Crossref record.
Abstract
This study was undertaken to compare the accuracies of the two-dimensional echocardiographic (2DE) and Doppler pressure half-time methods for the noninvasive estimation of cardiac catheterization measurements of mitral valve area in patients with pure mitral stenosis both with and without a previous commissurotomy. Data were retrospectively obtained from 74 consecutive patients who underwent cardiac catheterization within a 30 month period for evaluation of mitral stenosis, and who had two-dimensional echocardiograms performed before catheterization. Six patients (8.1%) had technically inadequate 2DE images and their data were excluded from analysis. Two of these patients had undergone commissurotomy, while the remaining four had not. Continuous-wave Doppler echocardiographic examinations were attempted in 45 patients and adequate measurements of pressure half-times were obtained in all patients studied. Mitral valve area by two-dimensional echocardiography was measured as the planimetered area along the inner border of the smallest mitral orifice visualized during short-axis scanning, while pressure half-time was calculated as the interval between the peak transmitral velocity and velocity/square root 2 as measured from the envelope of the Doppler spectral signal. Calculations from catheterization represented the minimal valve area at rest as derived from the Gorlin formula with the use of pressure gradients and thermodilution measurements of cardiac output. Thirty-seven of the patients had had a previous mitral commissurotomy a mean of 11.2 +/- 5.4 years before, while the remaining 37 patients were previously unoperated. Mean valve area as determined at catheterization for the total group of patients ranged from 0.37 to 2.30 cm2 (mean = 1.08 +/- 0.42 cm2).(ABSTRACT TRUNCATED AT 250 WORDS)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Interpretation of the correlation coefficient: A basic review
Taylor, R. (1990) · Journal of Diagnostic Medical Sonography · doi:10.1177/875647939000600106 · Cited by 2,390
Quiñones, M. A., Otto, C. M., Stoddard, M., Waggoner, A., & Zoghbi, W. A. (2002) · Journal of the American Society of Echocardiography · doi:10.1067/mje.2002.120202 · Cited by 2,130
American society of echocardiography
Ryan, T., & Khandheria, B. K. (2000) · Journal of the American Society of Echocardiography · doi:10.1016/s0894-7317(00)90052-x · Cited by 347
Metadata
- Authors
- Smith, M. D., Handshoe, R., Handshoe, S., Kwan, O. L., & DeMaria, A. N.
- Venue
- Circulation
- Published
- 1986-01
- Volume
- 73
- Issue
- 1
- Pages
- 100-107
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2013781046
- Cited by
- 177
- References
- 0
- FWCI
- 9.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparative accuracy of two-dimensional echocardiography and Doppler pressure half-time methods in assessing severity of mitral stenosis in patients with and without prior commissurotomy. https://app.cochat.ai/papers/10.1161/01.cir.73.1.100
- The paper
- Smith, M. D., Handshoe, R., Handshoe, S., Kwan, O. L., & DeMaria, A. N. (1986). Comparative accuracy of two-dimensional echocardiography and Doppler pressure half-time methods in assessing severity of mitral stenosis in patients with and without prior commissurotomy. Circulation. https://doi.org/10.1161/01.cir.73.1.100
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.