CoChat

Comparative accuracy of two-dimensional echocardiography and Doppler pressure half-time methods in assessing severity of mitral stenosis in patients with and without prior commissurotomy.

Smith, M D, Handshoe, R, Handshoe, S, Kwan, O L, DeMaria, A N · 1986 · Circulation
Cited by 177

The DOI matches its Crossref record.

Abstract

This study was undertaken to compare the accuracies of the two-dimensional echocardiographic (2DE) and Doppler pressure half-time methods for the noninvasive estimation of cardiac catheterization measurements of mitral valve area in patients with pure mitral stenosis both with and without a previous commissurotomy. Data were retrospectively obtained from 74 consecutive patients who underwent cardiac catheterization within a 30 month period for evaluation of mitral stenosis, and who had two-dimensional echocardiograms performed before catheterization. Six patients (8.1%) had technically inadequate 2DE images and their data were excluded from analysis. Two of these patients had undergone commissurotomy, while the remaining four had not. Continuous-wave Doppler echocardiographic examinations were attempted in 45 patients and adequate measurements of pressure half-times were obtained in all patients studied. Mitral valve area by two-dimensional echocardiography was measured as the planimetered area along the inner border of the smallest mitral orifice visualized during short-axis scanning, while pressure half-time was calculated as the interval between the peak transmitral velocity and velocity/square root 2 as measured from the envelope of the Doppler spectral signal. Calculations from catheterization represented the minimal valve area at rest as derived from the Gorlin formula with the use of pressure gradients and thermodilution measurements of cardiac output. Thirty-seven of the patients had had a previous mitral commissurotomy a mean of 11.2 +/- 5.4 years before, while the remaining 37 patients were previously unoperated. Mean valve area as determined at catheterization for the total group of patients ranged from 0.37 to 2.30 cm2 (mean = 1.08 +/- 0.42 cm2).(ABSTRACT TRUNCATED AT 250 WORDS)

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.73.1.100

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 177

Metadata

Authors
Smith, M. D., Handshoe, R., Handshoe, S., Kwan, O. L., & DeMaria, A. N.
Venue
Circulation
Published
1986-01
Volume
73
Issue
1
Pages
100-107
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2013781046
Cited by
177
References
0
FWCI
9.52
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparative accuracy of two-dimensional echocardiography and Doppler pressure half-time methods in assessing severity of mitral stenosis in patients with and without prior commissurotomy. https://app.cochat.ai/papers/10.1161/01.cir.73.1.100
The paper
Smith, M. D., Handshoe, R., Handshoe, S., Kwan, O. L., & DeMaria, A. N. (1986). Comparative accuracy of two-dimensional echocardiography and Doppler pressure half-time methods in assessing severity of mitral stenosis in patients with and without prior commissurotomy. Circulation. https://doi.org/10.1161/01.cir.73.1.100

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.