Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 296

The DOI matches its Crossref record.

Determinants of blood flow to vital organs during cardiopulmonary resuscitation in dogs.

Open access
Halperin, H R, Tsitlik, J E, Guerci, A D, Mellits, E D, Levin, H R, Shi, A Y, Chandra, N, Weisfeldt, M L·1986·Circulation

Abstract

Whether blood flow during cardiopulmonary resuscitation (CPR) results from intrathoracic pressure fluctuations or direct cardiac compression remains controversial. From modeling considerations, blood flow due to intrathoracic pressure fluctuations should be insensitive to compression rate over a wide range, but dependent on the applied force and compression duration. If direct compression of the heart plays a major role, however, flow should be dependent on compression rate and force, but above a threshold, insensitive to compression duration. These differences in hemodynamics produced by changes in rate and duration form a basis for determining whether blood flow during CPR results from intrathoracic pressure fluctuations or from direct cardiac compression. Manual CPR was studied in eight anesthetized, 21 to 32 kg dogs after induction of ventricular fibrillation. There was no surgical manipulation of the chest. Myocardial and cerebral blood flows were determined with radioactive microspheres. At nearly constant peak sternal force (378 to 426 newtons), flow was significantly increased when the duration of compression was increased from 14 +/- 1% to 46 +/- 3% of the cycle at a rate of 60/min. Flow was unchanged, however, after an increase in rate from 60 to 150/min at constant compression duration. The hemodynamics of manual CPR were next compared with those produced by vest inflation with simultaneous ventilation (vest CPR) in eight other dogs. Vest CPR changed intrathoracic pressure without direct cardiac compression, since sternal displacement was less than 0.8 cm. At a rate of 150/min, with similar duration and right atrial peak pressure, manual and vest CPR produced similar flow and perfusion pressures. Finally, the hemodynamics of manual CPR were compared with the hemodynamics of direct cardiac compression after thoracotomy. Cardiac deformation was measured and held nearly constant during changes in rate and duration. As opposed to changes accompanying manual CPR, there was no change in perfusion pressures when duration was increased from 15% to 45% of the cycle at a constant rate of 60/min. There was, however, a significant increase in perfusion pressures when rate was increased from 60 to 150/min at a constant duration of 45%. Thus, vital organ perfusion pressures and flow during manual external chest compression are dependent on the duration of compression, but not on rates of 60 or 150/min. These data are similar to those observed for vest CPR, where intrathoracic pressure is manipulated without sternal displacement, but opposite of those observed for direct cardiac compression.(ABSTRACT TRUNCATED AT 400 WORDS)

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.73.3.539

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 296

Metadata

Authors
Halperin, H. R., Tsitlik, J. E., Guerci, A. D., Mellits, E. D., Levin, H. R., Shi, A. Y., Chandra, N., & Weisfeldt, M. L.
Venue
Circulation
Published
1986-03
Volume
73
Issue
3
Pages
539-550
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W1994193077
Cited by
296
References
0
FWCI
14.02
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Determinants of blood flow to vital organs during cardiopulmonary resuscitation in dogs. https://app.cochat.ai/papers/10.1161/01.cir.73.3.539
The paper
Halperin, H. R., Tsitlik, J. E., Guerci, A. D., Mellits, E. D., Levin, H. R., Shi, A. Y., Chandra, N., & Weisfeldt, M. L. (1986). Determinants of blood flow to vital organs during cardiopulmonary resuscitation in dogs. Circulation. https://doi.org/10.1161/01.cir.73.3.539

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.