Ablation of cardiac tissues by an electrode catheter technique for treatment of ectopic supraventricular tachycardia in adults.
The DOI matches its Crossref record.
Abstract
Five patients with chronic or recurrent ectopic supraventricular tachycardias unresponsive to drugs underwent programmed stimulation, endocardial mapping, and attempted catheter ablation of the arrhythmia focus. For attempted ablation, an intracardiac electrode catheter was positioned near the exit point of the tachycardia and served as the cathode while a chest wall patch served as the anode. In two patients with tachycardia originating near the coronary sinus, discharges of 200 or 400 J each were delivered to two electrodes at the earliest area of endocardial activation. These two patients with incessant tachycardia remain free of tachycardia for 17 and 11 months, respectively. In one patient with tachycardia originating from the right atrial appendage, both catheter and surgical ablation proved unsuccessful in that a new focus of atrial tachycardia supervened. This patient subsequently underwent successful catheter ablation of the atrioventricular junction. Two patients with junctional tachycardia underwent catheter ablation of the atrioventricular junction. Complete atrioventricular block followed atrioventricular junctional ablation and these patients required permanent cardiac pacing. The junctional tachycardia was replaced by sinus rhythm with episodes of unsustained atrial tachycardia. However, after 13 +/- 5 months follow-up, neither of the patients require antiarrhythmic drugs. Catheter ablation can be effective for atrial foci near the coronary sinus os, and can be performed with preservation of atrioventricular conduction. Arrhythmia ablation is possible in those with atrioventricular junctional tachycardia but requires the sacrifice of atrioventricular conduction. After ablation, other automatic atrial foci may become operative and complicate use of dual-chamber pacemakers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Saoudi, N., Cosío, F., Waldo, A., Chen, S. A., Iesaka, Y., Lesh, M., Saksena, S., Salerno, J., & Schoels, W. (2001) · European Heart Journal · doi:10.1053/euhj.2001.2658 · Cited by 464
Schlüter, M., Geiger, M., Siebels, J., Duckeck, W., & Kuck, K. H. (1991) · Circulation · doi:10.1161/01.cir.84.4.1644 · Cited by 184
Percutaneous radiofrequency catheter ablation for supraventricular arrhythmias in children
Van Hare, G. F., Lesh, M. D., Scheinman, M., & Langberg, J. J. (1991) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(91)90656-t · Cited by 178
Self-citationTracy, C. M., Swartz, J. F., Fletcher, R. D., Hoops, H. G., Solomon, A. J., Karasik, P. E., & Mukherjee, D. (1993) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(93)90346-3 · Cited by 168
CHEN, S., TAI, C., CHIANG, C., DING, Y., & CHANG, M. S. (1998) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.1998.tb00924.x · Cited by 127
Metadata
- Authors
- Davis, J., Scheinman, M. M., Ruder, M. A., Griffin, J. C., Herre, J. M., Finkebeiner, W. E., Chin, M. C., & Eldar, M.
- Venue
- Circulation
- Published
- 1986-11
- Volume
- 74
- Issue
- 5
- Pages
- 1044-1053
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2058221114
- Cited by
- 44
- References
- 0
- FWCI
- 4.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ablation of cardiac tissues by an electrode catheter technique for treatment of ectopic supraventricular tachycardia in adults. https://app.cochat.ai/papers/10.1161/01.cir.74.5.1044
- The paper
- Davis, J., Scheinman, M. M., Ruder, M. A., Griffin, J. C., Herre, J. M., Finkebeiner, W. E., Chin, M. C., & Eldar, M. (1986). Ablation of cardiac tissues by an electrode catheter technique for treatment of ectopic supraventricular tachycardia in adults. Circulation. https://doi.org/10.1161/01.cir.74.5.1044
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.