The DOI matches its Crossref record.
Determination of stroke volume and cardiac output during exercise: comparison of two-dimensional and Doppler echocardiography, Fick oximetry, and thermodilution.
Open accessAbstract
Simultaneous estimates of cardiac output were made during graded upright maximal exercise in 10 male subjects by means of Doppler velocity spectrum of ascending aortic flow, apical two-dimensional echocardiograms, thermodilution, and Fick oximetry. In 15 subjects, aortic annular and root diameters were measured during similar exercise from parasternal two-dimensional echocardiograms. The linear correlation between Doppler, two-dimensional echocardiography, and the invasive estimates ranged from r = .78 to r = .92. Both echocardiographic techniques were able to predict changes in invasive flow estimates with reasonable accuracy. Two-dimensional echocardiographic flow estimates underestimated invasive values by about 60%. The accuracy of Doppler flow estimates varied with the method of estimating aortic cross-sectional area. Greatest accuracy was obtained with areas calculated from diameters measured at the aortic value anulus with the leading edge-to-leading edge method of measurement. Correlation coefficients comparing Doppler and thermodilution flow estimates were generally higher (r = .75 to .96, mean .86) for individuals than for the group, but accuracy of the Doppler estimates in single subjects was quite variable. Aortic diameters did not increase from rest to moderate levels of upright exercise. A 3% to 5% increase in resting aortic diameter was noted in the upright posture as compared with the supine. Doppler flow estimates were obtained in all subjects to maximal exertion but in only a minority of subjects with two-dimensional echocardiography or thermodilution. Thus two-dimensional and Doppler echocardiography offer a noninvasive means of estimating cardiac output during vigorous exercise. The Doppler technique is technically more suitable to the study of exercise than two-dimensional echocardiography.(ABSTRACT TRUNCATED AT 250 WORDS)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Methodological Guidelines for Impedance Cardiography
Sherwood(Chair), A., Allen, M. T., Fahrenberg, J., Kelsey, R. M., Lovallo, W. R., & van Doornen, L. J. P. (1990) · Psychophysiology · doi:10.1111/j.1469-8986.1990.tb02171.x · Cited by 1,169
An official European Respiratory Society statement: pulmonary haemodynamics during exercise
Kovacs, G., Herve, P., Barbera, J. A., Chaouat, A., Chemla, D., Condliffe, R., Garcia, G., Grünig, E., Howard, L., Humbert, M., et al. (2017) · European Respiratory Journal · doi:10.1183/13993003.00578-2017 · Cited by 307
Formenti, F., Beer, P. A., Croft, Q. P. P., Dorrington, K. L., Gale, D. P., Lappin, T. R. J., Lucas, G. S., Maher, E. R., Maxwell, P. H., McMullin, M. F., et al. (2011) · The FASEB Journal · doi:10.1096/fj.10-177378 · Cited by 92
Metadata
- Authors
- Christie, J., Sheldahl, L. M., Tristani, F. E., Sagar, K. B., Ptacin, M. J., & Wann, S.
- Venue
- Circulation
- Published
- 1987-09
- Volume
- 76
- Issue
- 3
- Pages
- 539-547
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2027253641
- Cited by
- 194
- References
- 0
- FWCI
- 21.61
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Determination of stroke volume and cardiac output during exercise: comparison of two-dimensional and Doppler echocardiography, Fick oximetry, and thermodilution. https://app.cochat.ai/papers/10.1161/01.cir.76.3.539
- The paper
- Christie, J., Sheldahl, L. M., Tristani, F. E., Sagar, K. B., Ptacin, M. J., & Wann, S. (1987). Determination of stroke volume and cardiac output during exercise: comparison of two-dimensional and Doppler echocardiography, Fick oximetry, and thermodilution. Circulation. https://doi.org/10.1161/01.cir.76.3.539
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.