CoChat

Hemodynamics of the Mueller maneuver in man: right and left heart micromanometry and Doppler echocardiography.

Condos, W R, Latham, R D, Hoadley, S D, Pasipoularides, A · 1987 · Circulation
Cited by 101

The DOI matches its Crossref record.

Abstract

Ten subjects with normal hemodynamics were studied during elective cardiac catheterization with right and left heart multisensor micromanometry to assess hemodynamic responses to the Mueller maneuver. Simultaneous right and left circulatory hemodynamics and left ventricular, pulmonary arterial, and aortic pressures were recorded, in addition to pulmonary arterial and aortic flow velocities. Steady-state cardiac outputs were determined by thermal dilution. Aortic systolic and mean pressures were not significantly changed during the Mueller maneuver, in contrast to a lower diastolic (p = .019) and higher pulse pressure (p = .016). Mean right atrial pressure (+/- SE) decreased from 7 +/- 1 to -17 +/- 4 mm Hg (p = .0002) and the right atrial "x" descent was markedly accentuated. Left ventricular end-diastolic pressure decreased from 12 +/- 4 to -3 +/- 13 mm Hg (p = .0025). Systemic vascular resistance and left ventricular peak positive dP/dt were increased during the Mueller maneuver (p less than .02), cardiac output and stroke volume were reduced (p less than .05), and there was no significant change in heart rate. Right and left peak flow velocities showed a trend toward a bilateral decrease (right, p = .054; left, p greater than .1), and times to peak flow velocity were increased in the pulmonary artery (p = .007) and reduced in the aortic root (p = .03). Normal subjects were studied separately by pulsed Doppler echocardiography. During the sustained Mueller maneuver, the internal jugular and right ventricular dimensions decreased, and superior vena cava Doppler flow was reduced.(ABSTRACT TRUNCATED AT 250 WORDS)

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.76.5.1020

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 101

Metadata

Authors
Condos, W. R., Latham, R. D., Hoadley, S. D., & Pasipoularides, A.
Venue
Circulation
Published
1987-11
Volume
76
Issue
5
Pages
1020-1028
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2066001267
Cited by
101
References
0
FWCI
4.27
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Hemodynamics of the Mueller maneuver in man: right and left heart micromanometry and Doppler echocardiography. https://app.cochat.ai/papers/10.1161/01.cir.76.5.1020
The paper
Condos, W. R., Latham, R. D., Hoadley, S. D., & Pasipoularides, A. (1987). Hemodynamics of the Mueller maneuver in man: right and left heart micromanometry and Doppler echocardiography. Circulation. https://doi.org/10.1161/01.cir.76.5.1020

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.