Hemodynamics of the Mueller maneuver in man: right and left heart micromanometry and Doppler echocardiography.
The DOI matches its Crossref record.
Abstract
Ten subjects with normal hemodynamics were studied during elective cardiac catheterization with right and left heart multisensor micromanometry to assess hemodynamic responses to the Mueller maneuver. Simultaneous right and left circulatory hemodynamics and left ventricular, pulmonary arterial, and aortic pressures were recorded, in addition to pulmonary arterial and aortic flow velocities. Steady-state cardiac outputs were determined by thermal dilution. Aortic systolic and mean pressures were not significantly changed during the Mueller maneuver, in contrast to a lower diastolic (p = .019) and higher pulse pressure (p = .016). Mean right atrial pressure (+/- SE) decreased from 7 +/- 1 to -17 +/- 4 mm Hg (p = .0002) and the right atrial "x" descent was markedly accentuated. Left ventricular end-diastolic pressure decreased from 12 +/- 4 to -3 +/- 13 mm Hg (p = .0025). Systemic vascular resistance and left ventricular peak positive dP/dt were increased during the Mueller maneuver (p less than .02), cardiac output and stroke volume were reduced (p less than .05), and there was no significant change in heart rate. Right and left peak flow velocities showed a trend toward a bilateral decrease (right, p = .054; left, p greater than .1), and times to peak flow velocity were increased in the pulmonary artery (p = .007) and reduced in the aortic root (p = .03). Normal subjects were studied separately by pulsed Doppler echocardiography. During the sustained Mueller maneuver, the internal jugular and right ventricular dimensions decreased, and superior vena cava Doppler flow was reduced.(ABSTRACT TRUNCATED AT 250 WORDS)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Hindricks, G., Potpara, T., Dagres, N., Arbelo, E., Bax, J. J., Blomström-Lundqvist, C., Boriani, G., Castella, M., Dan, G.-A., Dilaveris, P. E., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehaa612 · Cited by 9,971
Pathophysiology of Sleep Apnea
Dempsey, J. A., Veasey, S. C., Morgan, B. J., & O'Donnell, C. P. (2010) · Physiological Reviews · doi:10.1152/physrev.00043.2008 · Cited by 2,243
“Apneas produce multiple arrythmogenic factors: alterations in cardiac sympathetic and parasympathetic activities, myocardial hypoxemia (585), and intrathoracic pressure fluctuations that deform and alter the size of the cardiac chambers (108).”
BackgroundAssociation of Atrial Fibrillation and Obstructive Sleep Apnea
Gami, A. S., Pressman, G., Caples, S. M., Kanagala, R., Gard, J. J., Davison, D. E., Malouf, J. F., Ammash, N. M., Friedman, P. A., & Somers, V. K. (2004) · Circulation · doi:10.1161/01.cir.0000136587.68725.8e · Cited by 1,148
Obstructive Sleep Apnea and the Recurrence of Atrial Fibrillation
Kanagala, R., Murali, N. S., Friedman, P. A., Ammash, N. M., Gersh, B. J., Ballman, K. V., M. Shamsuzzaman, A. S., & Somers, V. K. (2003) · Circulation · doi:10.1161/01.cir.0000068337.25994.21 · Cited by 983
The sympathetic nervous system and obstructive sleep apnea: implications for hypertension
Narkiewicz, K., & Somers, V. K. (1997) · Journal of Hypertension · doi:10.1097/00004872-199715120-00062 · Cited by 254
Metadata
- Authors
- Condos, W. R., Latham, R. D., Hoadley, S. D., & Pasipoularides, A.
- Venue
- Circulation
- Published
- 1987-11
- Volume
- 76
- Issue
- 5
- Pages
- 1020-1028
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2066001267
- Cited by
- 101
- References
- 0
- FWCI
- 4.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Hemodynamics of the Mueller maneuver in man: right and left heart micromanometry and Doppler echocardiography. https://app.cochat.ai/papers/10.1161/01.cir.76.5.1020
- The paper
- Condos, W. R., Latham, R. D., Hoadley, S. D., & Pasipoularides, A. (1987). Hemodynamics of the Mueller maneuver in man: right and left heart micromanometry and Doppler echocardiography. Circulation. https://doi.org/10.1161/01.cir.76.5.1020
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.