Value and limitations of Doppler echocardiography in the quantification of stenotic mitral valve area: comparison of the pressure half-time and the continuity equation methods.

Nakatani, S, Masuyama, T, Kodama, K, Kitabatake, A, Fujii, K, Kamada, T·1988·Circulation

Abstract

Two Doppler methods, the pressure half-time method proposed by Hatle and the method based on the equation of continuity, were used to estimate stenotic mitral valve area noninvasively, and the accuracy of these methods was examined in patients with and without associated aortic regurgitation. Mitral valve area determined at catheterization by the Gorlin formula was used as a standard of reference. The study population consisted of 41 patients with mitral stenosis, and 20 of the 41 patients had associated aortic regurgitation. According to the equation of continuity, mitral valve area was determined as a product of aortic or pulmonic annular cross-sectional area and the ratio of time velocity integral of aortic or pulmonic flow to that of the mitral stenotic jet. Mitral valve area was determined by the pressure half-time method as 220/pressure half-time, the time from the peak transmitral velocity to one-half the square root of the peak velocity on the continuous-wave Doppler-determined transmitral flow velocity pattern. The pressure half-time method tended to overestimate catheterization measurements, and the correlation coefficient for this relation was .69 (SEE = 0.44 cm2). The correlation coefficient improved to .90 when the patients with associated aortic regurgitation were excluded. Mitral valve areas determined by the continuity equation method correlated well with catheterization measurements at a correlation coefficient of .91 (SEE = 0.24 cm2), irrespective of the presence of aortic regurgitation. The ratio of the time-velocity integral or aortic or pulmonic flow to the time-velocity integral of mitral stenotic jet also correlated well with mitral valve area determined by catheterization at a correlation coefficient of .84 (SEE = 0.10).(ABSTRACT TRUNCATED AT 250 WORDS)

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.77.1.78

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 250

Metadata

Authors
Nakatani, S., Masuyama, T., Kodama, K., Kitabatake, A., Fujii, K., & Kamada, T.
Venue
Circulation
Published
1988-01
Volume
77
Issue
1
Pages
78-85
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W1981635396
Cited by
250
References
0
FWCI
11.90
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Value and limitations of Doppler echocardiography in the quantification of stenotic mitral valve area: comparison of the pressure half-time and the continuity equation methods. https://app.cochat.ai/papers/10.1161/01.cir.77.1.78
The paper
Nakatani, S., Masuyama, T., Kodama, K., Kitabatake, A., Fujii, K., & Kamada, T. (1988). Value and limitations of Doppler echocardiography in the quantification of stenotic mitral valve area: comparison of the pressure half-time and the continuity equation methods. Circulation. https://doi.org/10.1161/01.cir.77.1.78

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.