The DOI matches its Crossref record.
Inaccuracy of mitral pressure half-time immediately after percutaneous mitral valvotomy. Dependence on transmitral gradient and left atrial and ventricular compliance.
Open accessAbstract
Mitral pressure half-time (T1/2) is widely used as an independent measure of mitral valve area in patients undergoing percutaneous mitral valvotomy. However, fluid dynamics theory predicts T1/2 to be strongly dependent on chamber compliance and the peak transmitral gradient, which are variables that change dramatically with valvotomy. These theoretical predictions were tested in an in vitro model of the left heart where valve area, chamber compliance, and initial gradient were independently adjusted. Measured T1/2 was observed to vary inversely with orifice area and directly with net chamber compliance and the square root of the initial pressure gradient. Theoretical predictions of T1/2 agreed with observed values with r = 0.998. To test this theory in vivo, the hemodynamic tracings of 18 patients undergoing mitral valvotomy were reviewed. Predictions were made for T1/2 assuming dependence only on valve area; these showed some correlations before valvotomy (r = 0.48-0.64, p less than 0.05) but none after valvotomy (r = 0.05-0.28, p = NS). Predictions for T1/2 based on the theoretical derivation (and thus including compliance and pressure in their calculation) were much better: before valvotomy, r = 0.93-0.96, p less than 0.0001; after valvotomy, r = 0.52-0.66, p less than 0.05. These data indicate that T1/2 is not an independent inverse measure of mitral valve area but is also directly proportional to net chamber compliance and the square root of the initial transmitral gradient. These other factors render T1/2 an unreliable measure of mitral valve area in the setting of acute mitral valvotomy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Bonow, R. O., Carabello, B. A., Chatterjee, K., de Leon, A. C., Faxon, D. P., Freed, M. D., Gaasch, W. H., Lytle, B. W., Nishimura, R. A., O’Gara, P. T., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.176857 · Cited by 8,495
Otto, C. M., Nishimura, R. A., Bonow, R. O., Carabello, B. A., Erwin, J. P., Gentile, F., Jneid, H., Krieger, E. V., Mack, M., McLeod, C., et al. (2021) · Circulation · doi:10.1161/cir.0000000000000923 · Cited by 3,686
2014 AHA/ACC Guideline for the Management of Patients With Valvular Heart Disease
Nishimura, R. A., Otto, C. M., Bonow, R. O., Carabello, B. A., Erwin, J. P., Guyton, R. A., O’Gara, P. T., Ruiz, C. E., Skubas, N. J., Sorajja, P., et al. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.02.536 · Cited by 3,523
Self-citationNishimura, R. A., Otto, C. M., Bonow, R. O., Carabello, B. A., Erwin, J. P., Guyton, R. A., O’Gara, P. T., Ruiz, C. E., Skubas, N. J., Sorajja, P., et al. (2014) · Circulation · doi:10.1161/cir.0000000000000031 · Cited by 2,905
Self-citationNishimura, R. A., Otto, C. M., Bonow, R. O., Carabello, B. A., Erwin, J. P., Guyton, R. A., O’Gara, P. T., Ruiz, C. E., Skubas, N. J., Sorajja, P., et al. (2014) · Circulation · doi:10.1161/cir.0000000000000029 · Cited by 2,566
Self-citation
Metadata
- Authors
- Thomas, J. D., Wilkins, G. T., Choong, C. Y., Abascal, V. M., Palacios, I. F., Block, P. C., & Weyman, A. E.
- Venue
- Circulation
- Published
- 1988-10
- Volume
- 78
- Issue
- 4
- Pages
- 980-993
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W1968385241
- Cited by
- 279
- References
- 0
- FWCI
- 11.26
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Inaccuracy of mitral pressure half-time immediately after percutaneous mitral valvotomy. Dependence on transmitral gradient and left atrial and ventricular compliance. https://app.cochat.ai/papers/10.1161/01.cir.78.4.980
- The paper
- Thomas, J. D., Wilkins, G. T., Choong, C. Y., Abascal, V. M., Palacios, I. F., Block, P. C., & Weyman, A. E. (1988). Inaccuracy of mitral pressure half-time immediately after percutaneous mitral valvotomy. Dependence on transmitral gradient and left atrial and ventricular compliance. Circulation. https://doi.org/10.1161/01.cir.78.4.980
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.