Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 229

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Long-term serial changes in left ventricular function and reversal of ventricular dilatation after valve replacement for chronic aortic regurgitation.

Open access
Bonow, R O, Dodd, J T, Maron, B J, O'Gara, P T, White, G G, McIntosh, C L, Clark, R E, Epstein, S E·1988·Circulation

Abstract

In most patients with aortic regurgitation, valve replacement results in reduction in left ventricular dilatation and an increase in ejection fraction. To determine the relation between serial changes in ventricular dilatation and changes in ejection fraction, we studied 61 patients with chronic severe aortic regurgitation by echocardiography and radionuclide angiography before, 6-8 months after, and 3-7 years after aortic valve replacement. Between preoperative and early postoperative studies, left ventricular end-diastolic dimension decreased (from 75 +/- 6 to 56 +/- 9 mm, p less than 0.001), peak systolic wall stress decreased (from 247 +/- 50 to 163 +/- 42 dynes x 10(3)/cm2), and ejection fraction increased (from 43 +/- 9% to 51 +/- 16%, p less than 0.001). Between early and late postoperative studies, diastolic dimension and peak systolic wall stress did not change, but ejection fraction increased further (to 56 +/- 19%, p less than 0.001). The increase in ejection fraction correlated with magnitude of reduction in diastolic dimension between preoperative and early postoperative studies (r = 0.63), between early and late postoperative studies (r = 0.54), and between preoperative and late postoperative studies (r = 0.69). Late increases in ejection fraction usually represented the continuation of an initial increase occurring early after operation. Thus, short-term and long-term improvement in left ventricular systolic function after operation is related significantly to the early reduction in left ventricular dilatation arising from correction of left ventricular volume overload. Moreover, late improvement in ejection fraction occurs commonly in patients with an early increase in ejection fraction after valve replacement but is unlikely to occur in patients with no change in ejection fraction during the first 6 months after operation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.78.5.1108

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 229

Metadata

Authors
Bonow, R. O., Dodd, J. T., Maron, B. J., O'Gara, P. T., White, G. G., McIntosh, C. L., Clark, R. E., & Epstein, S. E.
Venue
Circulation
Published
1988-11
Volume
78
Issue
5
Pages
1108-1120
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2007559384
Cited by
229
References
1
FWCI
4.83
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Long-term serial changes in left ventricular function and reversal of ventricular dilatation after valve replacement for chronic aortic regurgitation. https://app.cochat.ai/papers/10.1161/01.cir.78.5.1108
The paper
Bonow, R. O., Dodd, J. T., Maron, B. J., O'Gara, P. T., White, G. G., McIntosh, C. L., Clark, R. E., & Epstein, S. E. (1988). Long-term serial changes in left ventricular function and reversal of ventricular dilatation after valve replacement for chronic aortic regurgitation. Circulation. https://doi.org/10.1161/01.cir.78.5.1108

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.