The DOI matches its Crossref record.
Sustained bundle branch reentry as a mechanism of clinical tachycardia.
Abstract
The incidence of sustained bundle branch reentrant (BBR) tachycardia as a clinical or induced arrhythmia or both continues to be underreported. At our institution, BBR has been the underlying mechanism of sustained monomorphic ventricular tachycardia in approximately 6% of patients, whereas mechanisms unrelated to BBR were the cause in the rest. Data gathered from 20 consecutive patients showed electrophysiologic characteristics that suggest this possibility. These include induction of sustained monomorphic tachycardia with typical left or right bundle branch block morphology or both and atrioventricular dissociation or ventriculoatrial block. On intracardiac electrograms, all previously published criteria for BBR were fulfilled, and in addition, whenever there was a change in the cycle length of tachycardia, the His to His cycle length variation produced similar changes in ventricular activation during subsequent complexes with no relation to the preceding ventricular activation cycles. Compared with patients with ventricular tachycardia due to mechanisms unrelated to BBR, patients with BBR had frequent combination of nonspecific intraventricular conduction defects and prolonged HV intervals (100% vs. 11%, p less than 0.001). When this combination was associated with a tachycardia showing a left bundle branch block pattern, BBR accounted for the majority compared with mechanisms unrelated to BBR (73% vs. 27%, p less than 0.01). The above finding in patients with dilated cardiomyopathy should raise the suspicion of sustained BBR because dilated cardiomyopathy was observed in 95% of the patients with BBR. Twelve of the 20 patients were treated with antiarrhythmic agents, and the other eight were managed by selective catheter ablation of the right bundle branch with electrical energy. Our data suggest that sustained BBR is not an uncommon mechanism of tachycardia; it can be induced readily in the laboratory and is amendable to catheter ablation by the very nature of its circuit. The clinical and electrophysiologic features outlined in this study should enable one to correctly diagnose this important arrhythmia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Priori, S. G., Blomström-Lundqvist, C., Mazzanti, A., Blom, N., Borggrefe, M., Camm, J., Elliott, P. M., Fitzsimons, D., Hatala, R., Hindricks, G., et al. (2015) · European Heart Journal · doi:10.1093/eurheartj/ehv316 · Cited by 3,893
Zeppenfeld, K., Tfelt-Hansen, J., de Riva, M., Winkel, B. G., Behr, E. R., Blom, N. A., Charron, P., Corrado, D., Dagres, N., de Chillou, C., et al. (2022) · European Heart Journal · doi:10.1093/eurheartj/ehac262 · Cited by 3,140
Zipes, D. P., Camm, A. J., Borggrefe, M., Buxton, A. E., Chaitman, B., Fromer, M., Gregoratos, G., Klein, G., Moss, A. J., Myerburg, R. J., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.178233 · Cited by 1,080
EHRA/HRS Expert Consensus on Catheter Ablation of Ventricular Arrhythmias
Aliot, E. M., Stevenson, W. G., Almendral-Garrote, J. M., Bogun, F., Calkins, C. H., Delacretaz, E., Della Bella, P., Hindricks, G., Jaïs, P., Josephson, M. E., et al. (2009) · Heart Rhythm · doi:10.1016/j.hrthm.2009.04.030 · Cited by 770
Mapping and Ablation of Idiopathic Ventricular Fibrillation
Haïssaguerre, M., Shoda, M., Jaïs, P., Nogami, A., Shah, D. C., Kautzner, J., Arentz, T., Kalushe, D., Lamaison, D., Griffith, M., et al. (2002) · Circulation · doi:10.1161/01.cir.0000027564.55739.b1 · Cited by 686
Metadata
- Authors
- Caceres, J., Jazayeri, M., McKinnie, J., Avitall, B., Denker, S. T., Tchou, P., & Akhtar, M.
- Venue
- Circulation
- Published
- 1989-02
- Volume
- 79
- Issue
- 2
- Pages
- 256-270
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2050740516
- Cited by
- 317
- References
- 0
- FWCI
- 5.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Sustained bundle branch reentry as a mechanism of clinical tachycardia. https://app.cochat.ai/papers/10.1161/01.cir.79.2.256
- The paper
- Caceres, J., Jazayeri, M., McKinnie, J., Avitall, B., Denker, S. T., Tchou, P., & Akhtar, M. (1989). Sustained bundle branch reentry as a mechanism of clinical tachycardia. Circulation. https://doi.org/10.1161/01.cir.79.2.256
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.