CoChat

Percutaneous balloon valvuloplasty in patients with severe aortic stenosis and low ejection fraction. Immediate results and 1-year follow-up.

Open access
Berland, J, Cribier, A, Savin, T, Lefebvre, E, Koning, R, Letac, B · 1989 · Circulation
Cited by 70

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

The efficacy, morbidity, and 1-year follow-up of balloon aortic valvuloplasty in patients with low ejection fraction (less than 40%) were studied on a consecutive series of 55 patients (mean age, 77 years) treated from September 1985 to February 1987. Because of their age (20 patients greater than 80 years old), poor left ventricular function, and associated diseases, 45 patients were definitely not surgical candidates. Balloon dilatation with 15-23-mm diameter balloon catheters decreased the transvalvular gradient from 66 +/- 24 to 28 +/- 14 mm Hg (p less than 0.001) and increased the valve area from 0.47 +/- 0.15 to 0.83 +/- 0.27 cm2 (p less than 0.001). Immediately after dilatation, ejection fraction mildly increased from 29 +/- 7% to 34 +/- 9% (p less than 0.001) in 38 patients who had undergone a second left ventricular angiogram after dilatation. No significant change in the degree of aortic regurgitation was found after the procedure. Three patients died in hospital (femoral arterial complications in two, septicemia in one). Immediate clinical improvement was noted in 80% of the patients. During the follow-up (mean, 11 months), 22 patients died (heart failure in 15 patients, sudden death in five patients, myocardial infarction in one patient, cancer in one patient). Thirty patients survived, 21 with persistent clinical improvement. Repeat cardiac catheterization was performed at 6 months in 20 patients, of whom eight had recurrence of symptoms. Nine patients had restenosis: their hemodynamic indexes had returned to prevalvuloplasty values.(ABSTRACT TRUNCATED AT 250 WORDS)

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.79.6.1189

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 70

Metadata

Authors
Berland, J., Cribier, A., Savin, T., Lefebvre, E., Koning, R., & Letac, B.
Venue
Circulation
Published
1989-06
Volume
79
Issue
6
Pages
1189-1196
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W1980304669
Cited by
70
References
1
FWCI
4.90
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.