The DOI matches its Crossref record.
One-year follow-up results of the 1985-1986 National Heart, Lung, and Blood Institute's Percutaneous Transluminal Coronary Angioplasty Registry.
Open accessAbstract
In 1,801 patients in the 1985-1986 Percutaneous Transluminal Coronary Angioplasty Registry, overall 1-year mortality was 3.2%, the 1-year myocardial infarction rate was 7.2%, and the 1-year coronary artery bypass surgery rate was 13.2%. In the 78% of the cohort with all lesions successfully dilated and without major procedural complications (successful patients), the corresponding rates were 1.9%, 2.6%, and 6.4%. Nearly 20% of all deaths, 40% of all infarctions, and 25% of all bypass operations occurred in the small subset of patients (6.8%) who sustained periprocedural occlusion. Event rates were higher in patients with multivessel disease than in those with one-vessel disease. At 1 year, angina-free status was reported by approximately three fourths of all surviving patients, regardless of initial success. However, compared with successful patients, unsuccessful patients underwent intervening bypass surgery (42% vs. 6%) to achieve asymptomatic status more frequently. Comparison of the 1-year event rates in the 1985-1986 registry with those in the 1977-1981 registry indicated reductions in all major untoward events. These reductions became apparent after controlling for the more extensive disease of the 1985-1986 registry patients. In contrast, use of repeat angioplasty has increased by 50%. We conclude that the improved initial results reported in the 1985-1986 registry cohort were maintained at 1-year follow-up.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Braunwald, E., Antman, E. M., Beasley, J. W., Califf, R. M., Cheitlin, M. D., Hochman, J. S., Jones, R. H., Kereiakes, D., Kupersmith, J., Levin, T. N., et al. (2000) · Circulation · doi:10.1161/01.cir.102.10.1193 · Cited by 4,487
Self-citationBraunwald, E., Antman, E. M., Beasley, J. W., Califf, R. M., Cheitlin, M. D., Hochman, J. S., Jones, R. H., Kereiakes, D., Kupersmith, J., Levin, T. N., et al. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)00889-5 · Cited by 963
Self-citationDrew, B. J., Califf, R. M., Funk, M., Kaufman, E. S., Krucoff, M. W., Laks, M. M., Macfarlane, P. W., Sommargren, C., Swiryn, S., & Van Hare, G. F. (2004) · Circulation · doi:10.1161/01.cir.0000145144.56673.59 · Cited by 609
Participants, R. T. (1993) · The Lancet · doi:10.1016/0140-6736(93)90348-k · Cited by 598
Kip, K. E., Faxon, D. P., Detre, K. M., Yeh, W., Kelsey, S. F., & Currier, J. W. (1996) · Circulation · doi:10.1161/01.cir.94.8.1818 · Cited by 452
Self-citation
Metadata
- Authors
- Detre, K., Holubkov, R., Kelsey, S., Bourassa, M., Williams, D., Holmes, D., Dorros, G., Faxon, D., Myler, R., & Kent, K.
- Venue
- Circulation
- Published
- 1989-09
- Volume
- 80
- Issue
- 3
- Pages
- 421-428
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2084945610
- Cited by
- 212
- References
- 0
- FWCI
- 27.22
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: One-year follow-up results of the 1985-1986 National Heart, Lung, and Blood Institute's Percutaneous Transluminal Coronary Angioplasty Registry. https://app.cochat.ai/papers/10.1161/01.cir.80.3.421
- The paper
- Detre, K., Holubkov, R., Kelsey, S., Bourassa, M., Williams, D., Holmes, D., Dorros, G., Faxon, D., Myler, R., & Kent, K. (1989). One-year follow-up results of the 1985-1986 National Heart, Lung, and Blood Institute's Percutaneous Transluminal Coronary Angioplasty Registry. Circulation. https://doi.org/10.1161/01.cir.80.3.421
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.