Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 191

The DOI matches its Crossref record.

Ultrasonic tissue characterization with integrated backscatter. Acute myocardial ischemia, reperfusion, and stunned myocardium in patients.

Open access
Milunski, M R, Mohr, G A, Pérez, J E, Vered, Z, Wear, K A, Gessler, C J, Sobel, B E, Miller, J G, Wickline, S A·1989·Circulation

Abstract

We have previously shown in studies of experimental animals that myocardium exhibits a cardiac cycle-dependent variation of integrated backscatter that reflects regional myocardial contractile performance and that is blunted promptly after arterial occlusion and recovers after reperfusion. To define the clinical utility of ultrasonic tissue characterization with integrated backscatter for detection of acute myocardial infarction and reperfusion, 21 patients (14 men and seven women) were studied in the cardiac care unit within the first 24 hours (mean time, 11.3 hours; range, 3.5-23.8 hours) after the onset of symptoms indicative of acute myocardial infarction with conventional two-dimensional and M-mode echocardiography and with analysis of integrated backscatter. The magnitude of cyclic variation of integrated backscatter was measured from several sites within acute infarct regions and normal regions remote from the infarct zone for each patient. The average magnitude of cyclic variation among all patients (n = 21) was 4.8 +/- 0.5 dB in normal regions compared with 0.8 +/- 0.3 dB in infarct regions (p less than 0.05) within the first 24 hours after the onset of symptoms. Among the patients who had two studies, 15 (mean, 7.1 days; range, 2-31 days for second study) underwent coronary arteriography to define vessel patency. In patients with vessels with documented patency (n = 10), the magnitude of cyclic variation in infarct regions increased over time from 1.3 +/- 0.6 to 2.5 +/- 0.5 dB from the initial to final study (p less than 0.05). Patients with occluded infarct-related arteries (n = 5) exhibited no significant recovery of cyclic variation (0.3 +/- 0.3-0.6 +/- 0.3 dB). A blinded analysis of standard two-dimensional echocardiographic images revealed no significant recovery of wall thickening in either group over the same time intervals. Ultrasonic tissue characterization promptly detects acute myocardial infarction and may delineate potential beneficial effects of coronary artery reperfusion manifest by restoration of cyclic variation of integrated backscatter in the presence of severe wall motion abnormalities.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.80.3.491

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 191

Metadata

Authors
Milunski, M. R., Mohr, G. A., Pérez, J. E., Vered, Z., Wear, K. A., Gessler, C. J., Sobel, B. E., Miller, J. G., & Wickline, S. A.
Venue
Circulation
Published
1989-09
Volume
80
Issue
3
Pages
491-503
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2057089198
Cited by
191
References
0
FWCI
11.04
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Ultrasonic tissue characterization with integrated backscatter. Acute myocardial ischemia, reperfusion, and stunned myocardium in patients. https://app.cochat.ai/papers/10.1161/01.cir.80.3.491
The paper
Milunski, M. R., Mohr, G. A., Pérez, J. E., Vered, Z., Wear, K. A., Gessler, C. J., Sobel, B. E., Miller, J. G., & Wickline, S. A. (1989). Ultrasonic tissue characterization with integrated backscatter. Acute myocardial ischemia, reperfusion, and stunned myocardium in patients. Circulation. https://doi.org/10.1161/01.cir.80.3.491

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.