Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 190

The DOI matches its Crossref record.

Continuous wave Doppler echocardiographic measurement of prosthetic valve gradients. A simultaneous Doppler-catheter correlative study.

Burstow, D J, Nishimura, R A, Bailey, K R, Reeder, G S, Holmes, D R, Seward, J B, Tajik, A J · 1989 · Circulation

Abstract

Studies correlating prosthetic valve gradients determined by continuous wave Doppler echocardiography with gradients obtained by cardiac catheterization have, to date, been limited to patients with mitral and tricuspid prostheses or have compared nonsimultaneous measurements. Simultaneous Doppler and catheter pressure gradients in 36 patients (mean age, 63 +/- 13 years) with 42 prosthetic valves (20 aortic, 20 mitral, one tricuspid, and one pulmonary) were studied. Catheter gradients were obtained using a dual-catheter technique. The simultaneous pressure tracings and Doppler flow velocity profiles were digitized at 10-msec intervals to derive the corresponding maximal and mean gradients. The correlation between the maximal Doppler gradient and the simultaneously measured maximal catheter gradient was 0.94 (SEE = 6), and that between the Doppler gradient and the simultaneously measured mean catheter gradient was 0.96 (SEE = 3). There were no significant differences in correlation between gradients for the 32 mechanical valves (maximal gradients: r = 0.95, SEE = 6; mean gradients: r = 0.96, SEE = 3) and the 10 bioprosthetic valves (maximal gradients: r = 0.89, SEE = 6; mean gradients: r = 0.93, SEE = 3). In patients with mitral prostheses, Doppler gradients correlated well with the corresponding catheter gradients obtained with direct measurement of left atrial pressure (maximal gradients: r = 0.96, SEE = 2; mean gradients: r = 0.97, SEE = 1.2). A close correlation between corresponding Doppler and catheter gradients also was found in patients with aortic prostheses (maximal gradients: r = 0.94, SEE = 6; mean gradients: r = 0.94, SEE = 3). Thus, continuous wave Doppler echocardiography can accurately predict the pressure gradient across prosthetic valves.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.80.3.504

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 190

Metadata

Authors
Burstow, D. J., Nishimura, R. A., Bailey, K. R., Reeder, G. S., Holmes, D. R., Seward, J. B., & Tajik, A. J.
Venue
Circulation
Published
1989-09
Volume
80
Issue
3
Pages
504-514
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2002584910
Cited by
190
References
0
FWCI
8.75
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Continuous wave Doppler echocardiographic measurement of prosthetic valve gradients. A simultaneous Doppler-catheter correlative study. https://app.cochat.ai/papers/10.1161/01.cir.80.3.504
The paper
Burstow, D. J., Nishimura, R. A., Bailey, K. R., Reeder, G. S., Holmes, D. R., Seward, J. B., & Tajik, A. J. (1989). Continuous wave Doppler echocardiographic measurement of prosthetic valve gradients. A simultaneous Doppler-catheter correlative study. Circulation. https://doi.org/10.1161/01.cir.80.3.504

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.