Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 280

The DOI matches its Crossref record.

13N ammonia myocardial imaging at rest and with exercise in normal volunteers. Quantification of absolute myocardial perfusion with dynamic positron emission tomography.

Open access
Krivokapich, J, Smith, G T, Huang, S C, Hoffman, E J, Ratib, O, Phelps, M E, Schelbert, H R·1989·Circulation

Abstract

Positron emission tomography (PET) was applied to the measurement of myocardial perfusion using the perfusion tracer 13N-labeled ammonia. 13N ammonia was delivered intravenously to 13 healthy volunteers both at rest and during supine bicycle exercise. Dynamic PET imaging was obtained in three cross-sectional planes for 10 minutes commencing with each injection. The left ventricle was divided into eight sectors, and a small region of interest was assigned to the left ventricular blood pool to obtain the arterial input function. The net extraction of 13N ammonia was obtained for each sector by dividing the tissue 13N concentration at 10 minutes by the integral of the input function from the time of injection to 10 minutes. With this approach for calculating net extractions, rest and exercise net extractions were not significantly different from each other. To obviate possible overestimation of the true 13N ammonia input function by contamination by 13N-labeled compounds other than 13N ammonia or by spillover from myocardium into blood pool, the net extractions were calculated using only the first 90 seconds of the blood and tissue time-activity curves. This approach for calculating net extractions yielded significant differences between rest and exercise, with an average ratio of exercise to rest of 1.38 +/- 0.34. Nonetheless, the increase was less than predicted from the average 2.7-2.8-fold increase in double product at peak exercise or the 1.7-fold increase in double product at 1 minute after exercise. However, when the first 90 seconds of dynamic data were fit with a two compartment tracer kinetic model, average perfusion rates of 0.75 +/- 0.43 ml/min/g at rest and 1.50 +/- 0.74 ml/min/g with exercise were obtained. This average increase in perfusion of 2.2-fold corresponded to similar average increases in double product. Thus, the noninvasive technique of PET imaging with 13N ammonia shows promise for future applications in determining absolute flows in patients with coronary artery disease.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.80.5.1328

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 280

Metadata

Authors
Krivokapich, J., Smith, G. T., Huang, S. C., Hoffman, E. J., Ratib, O., Phelps, M. E., & Schelbert, H. R.
Venue
Circulation
Published
1989-11
Volume
80
Issue
5
Pages
1328-1337
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2098104480
Cited by
280
References
0
FWCI
9.86
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: 13N ammonia myocardial imaging at rest and with exercise in normal volunteers. Quantification of absolute myocardial perfusion with dynamic positron emission tomography. https://app.cochat.ai/papers/10.1161/01.cir.80.5.1328
The paper
Krivokapich, J., Smith, G. T., Huang, S. C., Hoffman, E. J., Ratib, O., Phelps, M. E., & Schelbert, H. R. (1989). 13N ammonia myocardial imaging at rest and with exercise in normal volunteers. Quantification of absolute myocardial perfusion with dynamic positron emission tomography. Circulation. https://doi.org/10.1161/01.cir.80.5.1328

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.