The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Left ventricular hypertrophy and impaired diastolic filling in essential hypertension. Diastolic mechanisms for systolic dysfunction during exercise.
Abstract
Left ventricular ejection fraction is normal at rest but may respond abnormally to exercise in many patients with essential hypertension. To assess the determinants of the abnormal ejection fraction response to exercise, we performed radionuclide angiography at rest and during exercise in 41 hypertensive patients without coronary artery disease. In 22 patients (group 1), the ejection fraction increased more than 5% during exercise; in the other 19 patients (group 2), the ejection fraction either increased by less than 5% or decreased with exercise. Left ventricular diastolic filling was impaired at rest in patients in group 2 compared with group 1, with reduced peak filling rate (2.5 +/- 0.4 vs. 3.1 +/- 0.7 end-diastolic volume/sec; p less than 0.01) and prolonged time to peak filling rate (175 +/- 28 vs. 153 +/- 22 msec; p less than 0.01). Impaired diastolic filling in group 2 was associated with less augmentation in end-diastolic volume during exercise compared with group 1 (p less than 0.01). These observations were not dependent on the threshold value that was arbitrarily chosen to define an abnormal ejection fraction response, as there were significant correlations for the entire group between the magnitude of change in ejection fraction with exercise and both the resting peak filling rate (r = 0.46) and the change in end-diastolic volume with exercise (r = 0.62).(ABSTRACT TRUNCATED AT 250 WORDS)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wall stress and patterns of hypertrophy in the human left ventricle.
Grossman, W., Jones, D., & McLaurin, L. P. (1975) · Journal of Clinical Investigation · doi:10.1172/jci108079 · Cited by 2,403
Cited by
Zile, M. R., & Brutsaert, D. L. (2002) · Circulation · doi:10.1161/hc1102.105289 · Cited by 1,184
Zile, M. R., & Brutsaert, D. L. (2002) · Circulation · doi:10.1161/hc1202.105290 · Cited by 887
Aurigemma, G. P., & Gaasch, W. H. (2004) · New England Journal of Medicine · doi:10.1056/nejmcp022709 · Cited by 764
Kitzman, D. W., Higginbotham, M. B., Cobb, F. R., Sheikh, K. H., & Sullivan, M. J. (1991) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(91)90832-t · Cited by 689
Oh, J. K., Appleton, C. P., Hatle, L. K., Nishimura, R. A., Seward, J. B., & Tajik, A. J. (1997) · Journal of the American Society of Echocardiography · doi:10.1016/s0894-7317(97)70062-2 · Cited by 629
Metadata
- Authors
- Cuocolo, A., Sax, F. L., Brush, J. E., Maron, B. J., Bacharach, S. L., & Bonow, R. O.
- Venue
- Circulation
- Published
- 1990-03
- Volume
- 81
- Issue
- 3
- Pages
- 978-986
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W1976652784
- Cited by
- 224
- References
- 1
- FWCI
- 10.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.