Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 312

The DOI matches its Crossref record.

Interstudy variability of coronary flow reserve. Influence of heart rate, arterial pressure, and ventricular preload.

McGinn, A L, White, C W, Wilson, R F·1990·Circulation

Abstract

To define the long-term variability of serial coronary flow reserve (CFR) measurements in humans and to evaluate the influence of changes in heart rate, mean arterial pressure, and left ventricular preload on CFR, 45 patients with normal left ventricular function (38 cardiac allograft recipients, five patients with normal coronary arteries, and two patients with minimal coronary artery disease [less than 50% diameter stenosis]) were studied. CFR (ratio of peak hyperemic [h] to resting [r] coronary blood flow velocity [CBFV]) was measured with a 3F coronary Doppler catheter and intracoronary papaverine. Initial CFR measurements were highly correlated with repeat measurements obtained 11 +/- 0.6 months later (r = 0.95; mean absolute difference, 0.3 +/- 0.1; n = 17). Differences in CFR between studies were related to changes in heart rate (r = 0.61, p = 0.01) but not to changes in mean arterial pressure (r = 0.25, p = 0.33). To define the effects of rapid changes in heart rate, mean arterial pressure, and preload on CFR, these variables were altered by atrial pacing, handgrip exercise, and volume expansion, respectively. Atrial pacing produced a rate-related increase in rCBFV but did not change hCBFV. Consequently, CFR was significantly reduced as heart rate was increased progressively from 76 +/- 2 in sinus rhythm (4.5 +/- 0.2) to 100 (3.8 +/- 0.2, p less than 0.05, n = 32) to 120 beats/min (3.2 +/- 0.1, p less than 0.05, n = 7). Despite a 19 +/- 2 mm Hg rise in mean arterial pressure during handgrip exercise, CFR was unchanged from baseline (3.7 +/- 0.3 vs. 3.7 +/- 0.4, p = NS, n = 7) because rCBFV rose proportionally with hCBFV. When pulmonary capillary wedge pressure was increased from 9 +/- 1 to 16 +/- 1 mm Hg after volume expansion, CFR was significantly decreased (from 3.8 +/- 0.2 to 2.9 +/- 0.2, p less than 0.05, n = 9) because rCBFV was increased while hCBFV remained unchanged. Hence, serial CFR measurements in humans are highly reproducible in the absence of conditions known to affect resting or hyperemic coronary blood flow. Increases in heart rate or preload reduced CFR because rCBFV was increased while hCBFV was unchanged. In contrast, changes in mean arterial pressure did not alter CFR. Proper interpretation of CFR measurements should take into account the hemodynamic conditions at which they are obtained.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.81.4.1319

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 312

Metadata

Authors
McGinn, A. L., White, C. W., & Wilson, R. F.
Venue
Circulation
Published
1990-04
Volume
81
Issue
4
Pages
1319-1330
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2089161547
Cited by
312
References
0
FWCI
15.24
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Interstudy variability of coronary flow reserve. Influence of heart rate, arterial pressure, and ventricular preload. https://app.cochat.ai/papers/10.1161/01.cir.81.4.1319
The paper
McGinn, A. L., White, C. W., & Wilson, R. F. (1990). Interstudy variability of coronary flow reserve. Influence of heart rate, arterial pressure, and ventricular preload. Circulation. https://doi.org/10.1161/01.cir.81.4.1319

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.