The DOI matches its Crossref record.
Relation of pulmonary vein to mitral flow velocities by transesophageal Doppler echocardiography. Effect of different loading conditions.
Abstract
It has previously been demonstrated that predictable changes occur in mitral flow velocities under different loading conditions. The purpose of this study was to relate changes in pulmonary venous and mitral flow velocities during different loading conditions as assessed by transesophageal echocardiography in the operating room. Nineteen patients had measurements of hemodynamics, that is, mitral and pulmonary vein flow velocities during the control situation, a decrease in preload by administration of nitroglycerin, an increase in preload by administration of fluids, and an increase in afterload by infusion of phenylephrine. There was a direct correlation between the changes in the mitral E velocity and the early peak diastolic velocity in the pulmonary vein curves (r = 0.61) as well as a direct correlation between the deceleration time of the mitral and pulmonary venous flow velocities in early diastole (r = 0.84). This indicates that diastolic flow velocity in the pulmonary vein is determined by the same factors that influence the mitral flow velocity curves. A decrease in preload caused a significant reduction in the initial E velocity and prolongation of deceleration time, and an increase in preload caused an increase in E velocity and shortening of deceleration time. An increase in afterload produced a variable effect on the initial E velocity and deceleration time and was dependent on the left ventricular filling pressure. The change in systolic forward flow velocity in the pulmonary vein was directly proportional to the change in cardiac output (r = 0.60). The pulmonary capillary wedge pressure correlated best with the flow velocity reversal in the pulmonary vein at atrial contraction (r = 0.81). Use of pulmonary vein velocities in conjunction with mitral flow velocities can help in understanding left ventricular filling.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Nagueh, S. F., Smiseth, O. A., Appleton, C. P., Byrd, B. F., Dokainish, H., Edvardsen, T., Flachskampf, F. A., Gillebert, T. C., Klein, A. L., Lancellotti, P., et al. (2016) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2016.01.011 · Cited by 5,262
Recommendations for the Evaluation of Left Ventricular Diastolic Function by Echocardiography
Nagueh, S. F., Appleton, C. P., Gillebert, T. C., Marino, P. N., Oh, J. K., Smiseth, O. A., Waggoner, A. D., Flachskampf, F. A., Pellikka, P. A., & Evangelista, A. (2009) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2008.11.023 · Cited by 4,367
Recommendations for the evaluation of left ventricular diastolic function by echocardiography
Nagueh, S. F., Appleton, C. P., Gillebert, T. C., Marino, P. N., Oh, J. K., Smiseth, O. A., Waggoner, A. D., Flachskampf, F. A., Pellikka, P. A., & Evangelisa, A. (2008) · European Journal of Echocardiography · doi:10.1093/ejechocard/jep007 · Cited by 3,351
Ommen, S. R., Nishimura, R. A., Appleton, C. P., Miller, F. A., Oh, J. K., Redfield, M. M., & Tajik, A. J. (2000) · Circulation · doi:10.1161/01.cir.102.15.1788 · Cited by 2,790
Self-citationAppleton, C. P., Jensen, J. L., Hatle, L. K., & Oh, J. K. (1997) · Journal of the American Society of Echocardiography · doi:10.1016/s0894-7317(97)70063-4 · Cited by 301
Self-citation
Metadata
- Authors
- Nishimura, R. A., Abel, M. D., Hatle, L. K., & Tajik, A. J.
- Venue
- Circulation
- Published
- 1990-05
- Volume
- 81
- Issue
- 5
- Pages
- 1488-1497
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2027656266
- Cited by
- 499
- References
- 0
- FWCI
- 20.92
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Relation of pulmonary vein to mitral flow velocities by transesophageal Doppler echocardiography. Effect of different loading conditions. https://app.cochat.ai/papers/10.1161/01.cir.81.5.1488
- The paper
- Nishimura, R. A., Abel, M. D., Hatle, L. K., & Tajik, A. J. (1990). Relation of pulmonary vein to mitral flow velocities by transesophageal Doppler echocardiography. Effect of different loading conditions. Circulation. https://doi.org/10.1161/01.cir.81.5.1488
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.