Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 198

The DOI matches its Crossref record.

Left ventricular volume measurement using cardiac axis nuclear magnetic resonance imaging. Validation by calibrated ventricular angiography.

Cranney, G B, Lotan, C S, Dean, L, Baxley, W, Bouchard, A, Pohost, G M·1990·Circulation

Abstract

Proton nuclear magnetic resonance (NMR) imaging has the potential to serially assess left ventricular (LV) volumes with optimal accuracy because it is a high-resolution, three-dimensional, noninvasive modality. Previous NMR studies to assess LV volumes have been suboptimal, as they have used either planes aligned with the axes of the body, which are compromised by partial volume effects, or spin-echo techniques that have been time-consuming to acquire and analyze. Accordingly, for LV volume measurement, we developed a gradient-echo (cine) NMR strategy that uses two orthogonal planes intersecting along the intrinsic long axis of the heart (two-chamber and four-chamber). This approach was validated against calibrated contrast biplane LV cineangiography (CATH) and also compared with a previously reported short-axis spin-echo NMR method. Twenty-one patients underwent CATH and NMR (long-axis, n = 21; short-axis, n = 14) within a 3-day interval. Although both long- and short-axis NMR LV volumes and ejection fractions correlated well with CATH (r greater than 0.90, p less than 0.001 in all), end-diastolic volumes by both long-axis (161 +/- 85 ml) and short-axis (151 +/- 81 ml) NMR were systematically less than those by CATH (182 +/- 85 ml) (p less than 0.05). Consequently, ejection fractions by long-axis (48 +/- 17%) and short-axis (49 +/- 17%) NMR consistently underestimated those by CATH (54 +/- 16%, p less than 0.05). End-systolic volumes by long-axis (94 +/- 71 ml) and short-axis (87 +/- 72 ml) NMR were not significantly different from those by CATH (92 +/- 69 ml). Both NMR techniques had low intraobserver and interobserver variation (less than 11%); however, short-axis spin-echo NMR involved longer acquisition/reconstruction (35 versus 18 minutes) and analysis (25 versus 10 minutes) times. We conclude that both short-axis spin-echo and long-axis gradient-echo NMR approaches reliably estimate LV volumes. Currently, the long-axis strategy appears more practical for clinical use because the scan and analysis times are relatively short.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.82.1.154

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 198

Metadata

Authors
Cranney, G. B., Lotan, C. S., Dean, L., Baxley, W., Bouchard, A., & Pohost, G. M.
Venue
Circulation
Published
1990-07
Volume
82
Issue
1
Pages
154-163
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2033155508
Cited by
198
References
0
FWCI
6.85
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Left ventricular volume measurement using cardiac axis nuclear magnetic resonance imaging. Validation by calibrated ventricular angiography. https://app.cochat.ai/papers/10.1161/01.cir.82.1.154
The paper
Cranney, G. B., Lotan, C. S., Dean, L., Baxley, W., Bouchard, A., & Pohost, G. M. (1990). Left ventricular volume measurement using cardiac axis nuclear magnetic resonance imaging. Validation by calibrated ventricular angiography. Circulation. https://doi.org/10.1161/01.cir.82.1.154

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.