CoChat

Minimum left ventricular pressure during beta-adrenergic stimulation in human subjects. Evidence for elastic recoil and diastolic "suction" in the normal heart.

Udelson, J E, Bacharach, S L, Cannon, R O, Bonow, R O · 1990 · Circulation
Cited by 141

The DOI matches its Crossref record.

Abstract

The influence of elastic recoil and restoring forces on diastolic left ventricular pressure decay and minimum left ventricular pressures has been demonstrated in animal models but has not been studied in the human heart. To investigate this issue in the normal human left ventricle, we studied eight patients with chest pain and normal coronary arteries with simultaneous measurement of left ventricular volume (by radionuclide angiography) and pressure (by micromanometer catheter) and coronary sinus blood flow. Electrocardiographic-gated data were obtained in the basal state, during rapid atrial pacing, and during isoproterenol infusion to a similar heart rate. Compared with pacing, isoproterenol increased ejection fraction and reduced end-systolic volume (p less than 0.005), end-systolic pressure (p less than 0.005), and the half-time of pressure decline after peak negative dP/dt (T1/2) (p less than 0.001). Negative diastolic pressure developed in seven of eight patients during isoproterenol (range, -0.5 to -2.4 mm Hg) but in only one of eight during pacing (-0.2 mm Hg). These reduced diastolic pressures during isoproterenol were accompanied by increased stroke volume (reflecting increased transmitral flow) and diminished pulmonary wedge pressure (reflecting left atrial pressure). The magnitude of reduction in minimum diastolic pressure during pacing and isoproterenol was related to the change in end-systolic volume (r = 0.79, p less than 0.001), ejection fraction (r = -0.74, p less than 0.001), T1/2 (r = -0.57, p less than 0.02), and coronary sinus flow (r = 0.73, p less than 0.005). Stronger correlations were observed in analyzing changes during isoproterenol alone.(ABSTRACT TRUNCATED AT 250 WORDS)

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.82.4.1174

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 141

Metadata

Authors
Udelson, J. E., Bacharach, S. L., Cannon, R. O., & Bonow, R. O.
Venue
Circulation
Published
1990-10
Volume
82
Issue
4
Pages
1174-1182
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W1971902230
Cited by
141
References
0
FWCI
6.61
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Minimum left ventricular pressure during beta-adrenergic stimulation in human subjects. Evidence for elastic recoil and diastolic "suction" in the normal heart. https://app.cochat.ai/papers/10.1161/01.cir.82.4.1174
The paper
Udelson, J. E., Bacharach, S. L., Cannon, R. O., & Bonow, R. O. (1990). Minimum left ventricular pressure during beta-adrenergic stimulation in human subjects. Evidence for elastic recoil and diastolic "suction" in the normal heart. Circulation. https://doi.org/10.1161/01.cir.82.4.1174

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.