Minimum left ventricular pressure during beta-adrenergic stimulation in human subjects. Evidence for elastic recoil and diastolic "suction" in the normal heart.
The DOI matches its Crossref record.
Abstract
The influence of elastic recoil and restoring forces on diastolic left ventricular pressure decay and minimum left ventricular pressures has been demonstrated in animal models but has not been studied in the human heart. To investigate this issue in the normal human left ventricle, we studied eight patients with chest pain and normal coronary arteries with simultaneous measurement of left ventricular volume (by radionuclide angiography) and pressure (by micromanometer catheter) and coronary sinus blood flow. Electrocardiographic-gated data were obtained in the basal state, during rapid atrial pacing, and during isoproterenol infusion to a similar heart rate. Compared with pacing, isoproterenol increased ejection fraction and reduced end-systolic volume (p less than 0.005), end-systolic pressure (p less than 0.005), and the half-time of pressure decline after peak negative dP/dt (T1/2) (p less than 0.001). Negative diastolic pressure developed in seven of eight patients during isoproterenol (range, -0.5 to -2.4 mm Hg) but in only one of eight during pacing (-0.2 mm Hg). These reduced diastolic pressures during isoproterenol were accompanied by increased stroke volume (reflecting increased transmitral flow) and diminished pulmonary wedge pressure (reflecting left atrial pressure). The magnitude of reduction in minimum diastolic pressure during pacing and isoproterenol was related to the change in end-systolic volume (r = 0.79, p less than 0.001), ejection fraction (r = -0.74, p less than 0.001), T1/2 (r = -0.57, p less than 0.02), and coronary sinus flow (r = 0.73, p less than 0.005). Stronger correlations were observed in analyzing changes during isoproterenol alone.(ABSTRACT TRUNCATED AT 250 WORDS)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The pathophysiology of heart failure with preserved ejection fraction
Borlaug, B. A. (2014) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2014.83 · Cited by 726
Hemodynamic determinants of the mitral annulus diastolic velocities by tissue Doppler
Nagueh, S. F., Sun, H., Kopelen, H. A., Middleton, K. J., & Khoury, D. S. (2001) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)01056-1 · Cited by 540
Bonow, R. O., & Udelson, J. E. (1992) · Annals of Internal Medicine · doi:10.7326/0003-4819-117-6-502 · Cited by 399
Self-citationBiondi, B., Palmieri, E. A., Lombardi, G., & Fazio, S. (2002) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem.87.3.8302 · Cited by 245
Cuocolo, A., Sax, F. L., Brush, J. E., Maron, B. J., Bacharach, S. L., & Bonow, R. O. (1990) · Circulation · doi:10.1161/01.cir.81.3.978 · Cited by 224
Self-citation
Metadata
- Authors
- Udelson, J. E., Bacharach, S. L., Cannon, R. O., & Bonow, R. O.
- Venue
- Circulation
- Published
- 1990-10
- Volume
- 82
- Issue
- 4
- Pages
- 1174-1182
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W1971902230
- Cited by
- 141
- References
- 0
- FWCI
- 6.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Minimum left ventricular pressure during beta-adrenergic stimulation in human subjects. Evidence for elastic recoil and diastolic "suction" in the normal heart. https://app.cochat.ai/papers/10.1161/01.cir.82.4.1174
- The paper
- Udelson, J. E., Bacharach, S. L., Cannon, R. O., & Bonow, R. O. (1990). Minimum left ventricular pressure during beta-adrenergic stimulation in human subjects. Evidence for elastic recoil and diastolic "suction" in the normal heart. Circulation. https://doi.org/10.1161/01.cir.82.4.1174
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.