Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 172

The DOI matches its Crossref record.

Doppler echocardiographic assessment of the St. Jude Medical prosthetic valve in the aortic position using the continuity equation.

Open access
Chafizadeh, E R, Zoghbi, W A·1991·Circulation

Abstract

To test whether the continuity equation can be applied to the noninvasive assessment of prosthetic aortic valve function, Doppler echocardiography was performed in 67 patients (mean age, 58 +/- 14 years) within 10 +/- 6 days after valve replacement with St. Jude Medical valves. All patients were clinically stable and without evidence of valve dysfunction. Valve size ranged from 19 to 31 mm, and ejection fraction ranged from 30% to 75%. With the parasternal long-axis view, the left ventricular outflow diameter measured just proximal to the prosthetic valve correlated well with valve size (r = 0.92). Doppler-derived maximal gradients ranged from 9 to 71 mm Hg. Effective prosthetic aortic valve area by the continuity equation ranged between 0.73 cm2 for a 19-mm valve and 4.23 cm2 for a 31-mm valve. With analysis of variance, effective orifice area differentiated various valve sizes (p less than 10(-14)) better than did gradients alone (p = 0.003) and correlated better with actual valve orifice area (r = 0.83 versus - 0.40). A Doppler velocity index, the ratio of peak velocity in the left ventricular outflow to that of the aortic jet, averaged 0.41 +/- 0.09 and was less dependent on valve size (r = 0.43). Thus, the continuity equation can be applied to the assessment of prosthetic St. Jude valves in the aortic position. By accounting for flow through the valve, it provides an improved assessment over the sole use of gradients in the evaluation of prosthetic valve function.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.83.1.213

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 172

Metadata

Authors
Chafizadeh, E. R., & Zoghbi, W. A.
Venue
Circulation
Published
1991-01
Volume
83
Issue
1
Pages
213-223
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2041879433
Cited by
172
References
0
FWCI
5.10
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Doppler echocardiographic assessment of the St. Jude Medical prosthetic valve in the aortic position using the continuity equation. https://app.cochat.ai/papers/10.1161/01.cir.83.1.213
The paper
Chafizadeh, E. R., & Zoghbi, W. A. (1991). Doppler echocardiographic assessment of the St. Jude Medical prosthetic valve in the aortic position using the continuity equation. Circulation. https://doi.org/10.1161/01.cir.83.1.213

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.