The DOI matches its Crossref record.
Transesophageal Doppler echocardiography evaluation of coronary blood flow velocity in baseline conditions and during dipyridamole-induced coronary vasodilation.
Abstract
Transesophageal echocardiography allows the evaluation of proximal coronary artery anatomy and coronary blood flow velocity (CBFV). To assess the potential of transesophageal echocardiography in evaluating CBFV and its variations induced by coronary-active drugs, we studied 15 patients by high-quality pulsed wave Doppler recordings of CBFV. In these patients, transesophageal Doppler evaluation of CBFV was performed before, 2 minutes after cessation of dipyridamole infusion (0.56 mg/kg in 4 minutes), and 2 minutes after aminophylline infusion (240 mg injected 4 minutes after cessation of dipyridamole infusion). The following CBFV parameters were evaluated at each of the three steps of the study protocol: maximal and mean diastolic velocities and maximal and mean systolic velocities. Furthermore, the following indexes of coronary flow reserve were evaluated: the ratio between maximal diastolic velocity recorded after and before dipyridamole administration and the ratio between mean diastolic velocity recorded after and before dipyridamole administration. Nine of the 15 patients had a normal left anterior descending coronary artery (group A), whereas the remaining six had significant (less than or equal to 75%) stenosis (group B). In group A patients, all CBFV parameters increased significantly during dipyridamole infusion and returned to near baseline values after aminophylline infusion. In group B patients, on the other hand, none of the CBFV parameters increased after dipyridamole infusion. Dipyridamole/baseline maximal diastolic velocity and mean diastolic velocity ratios were, respectively, 3.22 +/- 0.96 and 3.04 +/- 0.88 in group A and 1.46 +/- 0.45 (p less than 0.01 versus group A) and 1.48 +/- 0.49 (p less than 0.01 versus group A) in group B patients.(ABSTRACT TRUNCATED AT 250 WORDS)
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Validation of a Doppler guide wire for intravascular measurement of coronary artery flow velocity.
Doucette, J. W., Corl, P. D., Payne, H. M., Flynn, A. E., Goto, M., Nassi, M., & Segal, J. (1992) · Circulation · doi:10.1161/01.cir.85.5.1899 · Cited by 1,016
Caiati, C., Montaldo, C., Zedda, N., Bina, A., & Iliceto, S. (1999) · Circulation · doi:10.1161/01.cir.99.6.771 · Cited by 347
Self-citationHildick-Smith, D. J. R. (2000) · Heart · doi:10.1136/heart.84.4.383 · Cited by 80
Metadata
- Authors
- Iliceto, S., Marangelli, V, Memmola, C., & Rizzon, P.
- Venue
- Circulation
- Published
- 1991-01
- Volume
- 83
- Issue
- 1
- Pages
- 61-69
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W1991336736
- Cited by
- 294
- References
- 0
- FWCI
- 12.90
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Transesophageal Doppler echocardiography evaluation of coronary blood flow velocity in baseline conditions and during dipyridamole-induced coronary vasodilation. https://app.cochat.ai/papers/10.1161/01.cir.83.1.61
- The paper
- Iliceto, S., Marangelli, V, Memmola, C., & Rizzon, P. (1991). Transesophageal Doppler echocardiography evaluation of coronary blood flow velocity in baseline conditions and during dipyridamole-induced coronary vasodilation. Circulation. https://doi.org/10.1161/01.cir.83.1.61
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.