Dipyridamole thallium-201 scintigraphy as a preoperative screening test. A reexamination of its predictive potential. Study of Perioperative Ischemia Research Group.

Mangano, D T, London, M J, Tubau, J F, Browner, W S, Hollenberg, M, Krupski, W, Layug, E L, Massie, B·1991·Circulation

Abstract

BACKGROUND: We examined the value of dipyridamole thallium-201 (201Tl) scintigraphy as a preoperative screening test for perioperative myocardial ischemia and infarction. METHODS AND RESULTS: We prospectively studied 60 patients undergoing elective vascular surgery. We performed 201Tl scintigraphy preoperatively and blinded all treating physicians to the results. Historical, clinical, laboratory, and physiological data were gathered throughout hospitalization. Myocardial ischemia was assessed during the intraoperative period using continuous 12-lead electrocardiography (ECG) and transesophageal echocardiography (TEE) and during the postoperative period using continuous two-lead ambulatory ECG. Adverse cardiac outcomes (cardiac death, myocardial infarction, unstable angina, severe ischemia, or congestive heart failure) were assessed daily throughout hospitalization. Twenty-two patients (37%) had defects that improved or reversed on delayed scintigrams (redistribution defects), 18 (30%) had persistent defects, and 20 (33%) had no defects on 201Tl scintigraphy. There was no association between redistribution defects and adverse cardiac outcomes: 54% (seven of 13) of adverse outcomes occurred in patients without redistribution defects, and the risk of an adverse outcome was not significantly increased in patients with redistribution defects (relative risk 1.5, 95% confidence interval 0.6-3.9, p = 0.43). Consistent with these findings, there was also no association between redistribution defects and perioperative ischemia: 54% (19 of all 35) of perioperative ECG and TEE ischemic episodes and 58% (14 of 24) of severe ischemic episodes occurred in patients without redistribution defects. The sensitivity of 201Tl scintigraphy for perioperative ischemia and adverse outcomes ranged from 40% to 54%, specificity from 65% to 71%, positive predictive value from 27% to 47% and negative predictive value from 61% to 82%. CONCLUSIONS: These results differ from those of previous studies and suggest that the routine use of 201Tl scintigraphy for preoperative screening of patients undergoing vascular surgery may not be warranted.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.84.2.493

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 240

Metadata

Authors
Mangano, D. T., London, M. J., Tubau, J. F., Browner, W. S., Hollenberg, M., Krupski, W., Layug, E. L., & Massie, B.
Venue
Circulation
Published
1991-08
Volume
84
Issue
2
Pages
493-502
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2040750186
Cited by
240
References
1
FWCI
23.31
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Dipyridamole thallium-201 scintigraphy as a preoperative screening test. A reexamination of its predictive potential. Study of Perioperative Ischemia Research Group. https://app.cochat.ai/papers/10.1161/01.cir.84.2.493
The paper
Mangano, D. T., London, M. J., Tubau, J. F., Browner, W. S., Hollenberg, M., Krupski, W., Layug, E. L., & Massie, B. (1991). Dipyridamole thallium-201 scintigraphy as a preoperative screening test. A reexamination of its predictive potential. Study of Perioperative Ischemia Research Group. Circulation. https://doi.org/10.1161/01.cir.84.2.493

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.