The DOI matches its Crossref record.
Prevention of restenosis after percutaneous transluminal coronary angioplasty with thromboxane A2-receptor blockade. A randomized, double-blind, placebo-controlled trial. Coronary Artery Restenosis Prevention on Repeated Thromboxane-Antagonism Study (CARPORT).
Open accessAbstract
BACKGROUND: GR32191B is a novel thromboxane A2-receptor antagonist with potent antiagregational and antivasoconstrictive properties. We have conducted a randomized, double-blind placebo-controlled trial to study its usefulness in restenosis prevention. METHODS AND RESULTS: Patients received either GR32191B (80 mg orally before angioplasty and 80 mg/day orally for 6 months) or 250 mg i.v. aspirin before angioplasty and placebo for 6 months. Coronary angiograms before angioplasty, after angioplasty, and at 6-month follow-up were quantitatively analyzed. Angioplasty was attempted in 697 patients. For efficacy analysis, quantitative angiography at follow-up was available in 522 compliant patients (261 in each group). Baseline clinical and angiographic parameters did not differ between the two treatment groups. The mean difference in coronary diameter between postangioplasty and follow-up angiogram (primary end point) was -0.31 +/- 0.54 mm in the control group and -0.31 +/- 0.55 mm in the GR32191B group. Clinical events during 6-month follow-up, analyzed on intention-to-treat basis, were ranked according to the highest category on a scale ranging from death (control, six; GR32191B, four) to nonfatal infarction (control, 22; GR32191B, 18), bypass grafting (control, 19; GR32191B, 22) and repeat angioplasty (control, 52; GR32191B, 48). No significant difference in ranking was detected. Six months after angioplasty, 75% of patients in the GR32191B group and 72% of patients in the control group were symptom free. CONCLUSIONS: Long-term thromboxane A2-receptor blockade with GR32191B does not prevent restenosis and does not favorably influence the clinical course after angioplasty.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Smith, S. C., Dove, J. T., Jacobs, A. K., Kennedy, J. W., Kereiakes, D., Kern, M. J., Kuntz, R. E., Popma, J. J., Schaff, H. V., Williams, D. O., et al. (2001) · Circulation · doi:10.1161/01.cir.103.24.3019 · Cited by 608
Percutaneous Transluminal Coronary Angioplasty
Landau, C., Lange, R. A., & Hillis, L. D. (1994) · New England Journal of Medicine · doi:10.1056/nejm199404073301407 · Cited by 445
Clinical and quantitative coronary angiographic predictors of coronary restenosis
Mercado, N., Boersma, E., Wijns, W., Gersh, B. J., Morillo, C. A., de Valk, V., van Es, G.-A., Grobbee, D. E., & Serruys, P. W. (2001) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(01)01431-0 · Cited by 175
Self-citation
Metadata
- Authors
- Serruys, P. W., Rutsch, W., Heyndrickx, G. R., Danchin, N., Mast, E. G., Wijns, W., Rensing, B. J., Vos, J., & Stibbe, J.
- Venue
- Circulation
- Published
- 1991-10
- Volume
- 84
- Issue
- 4
- Pages
- 1568-1580
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W1965967389
- Cited by
- 236
- References
- 0
- FWCI
- 27.88
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Prevention of restenosis after percutaneous transluminal coronary angioplasty with thromboxane A2-receptor blockade. A randomized, double-blind, placebo-controlled trial. Coronary Artery Restenosis Prevention on Repeated Thromboxane-Antagonism Study (CARPORT). https://app.cochat.ai/papers/10.1161/01.cir.84.4.1568
- The paper
- Serruys, P. W., Rutsch, W., Heyndrickx, G. R., Danchin, N., Mast, E. G., Wijns, W., Rensing, B. J., Vos, J., & Stibbe, J. (1991). Prevention of restenosis after percutaneous transluminal coronary angioplasty with thromboxane A2-receptor blockade. A randomized, double-blind, placebo-controlled trial. Coronary Artery Restenosis Prevention on Repeated Thromboxane-Antagonism Study (CARPORT). Circulation. https://doi.org/10.1161/01.cir.84.4.1568
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.