CoChat

Predictors of in-hospital mortality after DC catheter ablation of atrioventricular junction. Results of a prospective, international, multicenter study.

Evans, G T, Scheinman, M M, Bardy, G, Borggrefe, M, Brugada, P, Fisher, J, Fontaine, G, Huang, S K, Huang, W H, Josephson, M · 1991 · Circulation
Cited by 128

The DOI matches its Crossref record.

Abstract

BACKGROUND: The Catheter Ablation Registry was the first international, multicenter, prospective study of the safety and efficacy of catheter ablation. METHODS AND RESULTS: From August 1987 through March 1990, the study comprised 136 patients in whom only DC energy was used in attempted production of third-degree atrioventricular block to treat uncontrollable supraventricular tachycardias. Eight patients died during hospitalization for ablation. In seven (5.1%), the ablation may have contributed to their deaths. Causes of death included ventricular fibrillation (five patients, three with polymorphic ventricular tachycardia), progressive heart failure (one patient), and respiratory failure (two patients, one dying after resuscitation from ventricular fibrillation). Compared with survivors, patients who died were more likely to have had prior aborted sudden death (38% versus 2%, p less than 0.05), congestive heart failure (88% versus 22%, p less than 0.001), cardiomyopathy (50% versus 16%, p less than 0.05), lower baseline systolic blood pressure (106 versus 138 mm Hg, p less than 0.001), prolonged baseline and postablation corrected QT interval (p less than 0.01), and markedly reduced ejection fraction (27% versus 52%, p less than 0.001). Ablation successfully produced third-degree atrioventricular block in 88% of the patients who died and in 83% of survivors. CONCLUSIONS: Catheter ablation of the atrioventricular junction with DC energy carries a significant, previously unrecognized risk of death (5.1%), particularly from lethal arrhythmias, when applied to patients with severe left ventricular dysfunction. Great care should be taken in these seriously ill patients to guard against postablation ventricular arrhythmias.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.84.5.1924

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 128

Metadata

Authors
Evans, G. T., Scheinman, M. M., Bardy, G., Borggrefe, M., Brugada, P., Fisher, J., Fontaine, G., Huang, S. K., Huang, W. H., & Josephson, M.
Venue
Circulation
Published
1991-11
Volume
84
Issue
5
Pages
1924-1937
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2028922467
Cited by
128
References
0
FWCI
8.16
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Predictors of in-hospital mortality after DC catheter ablation of atrioventricular junction. Results of a prospective, international, multicenter study. https://app.cochat.ai/papers/10.1161/01.cir.84.5.1924
The paper
Evans, G. T., Scheinman, M. M., Bardy, G., Borggrefe, M., Brugada, P., Fisher, J., Fontaine, G., Huang, S. K., Huang, W. H., & Josephson, M. (1991). Predictors of in-hospital mortality after DC catheter ablation of atrioventricular junction. Results of a prospective, international, multicenter study. Circulation. https://doi.org/10.1161/01.cir.84.5.1924

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.