CoChat

Use of radiofrequency current to ablate accessory connections in children.

Open access
Dick, M, O'Connor, B K, Serwer, G A, LeRoy, S, Armstrong, B · 1991 · Circulation
Cited by 125

The DOI matches its Crossref record.

Abstract

BACKGROUND: Several investigators have recently ablated electrophysiologically mapped accessory connections in the adult human myocardium by using radiofrequency current. To examine the effectiveness and safety of radiofrequency current for ablation of accessory connections in children, 20 consecutive patients (age, 3-18 years) with preexcitation and/or supraventricular tachycardia were evaluated by electrophysiological study. METHODS AND RESULTS: Nineteen of the 20 patients were completely studied and demonstrated accessory connections. After identification of the earliest retrograde atrial activation site, a steerable 7F catheter (with a 4-mm-long electrode at the distal tip) was placed within the ventricular cavity ipsilateral to the accessory connection and positioned at the atrioventricular valve annulus directly opposite the earliest point of retrograde atrial activation. Radiofrequency current was delivered at 50-65 volts for 10-60 seconds at a frequency of 500 kHz. Radiofrequency pulses were delivered for two to 26 trials. Upon completion of radiofrequency trials, repeat electrophysiological testing was performed. Thirteen of 19 subjects (68%) experienced definite successful ablation of their accessory pathway; an additional patient had probable successful ablation, yielding an overall success rate of 74%. Eighty-seven percent of individuals with a left-sided pathway had permanent ablation and 100% with a manifest left-sided pathway experienced successful ablation. Only 29% of the first seven patients had a successful result; in contrast, 92% of the next 12 patients had successful interruption of their accessory pathways. After ablation, 4-day continuous electrocardiographic telemetry disclosed no significant arrhythmias. CPK enzyme rises peaked at 12-24 hours. The rise was excessive and associated with general anesthesia in five patients. The isoenzyme MB fraction rose mildly in five other patients and returned to normal within 72 hours. No clinical or electrocardiographic evidence of myocardial ischemia was detected. Follow-up for 4-12 months indicates no return of preexcitation or tachycardia in any patient whose accessory connection was successfully ablated. CONCLUSIONS: This experience indicates that radiofrequency current is an effective and safe technique for ablation of accessory connections in children.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.84.6.2318

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 125

Metadata

Authors
Dick, M., O'Connor, B. K., Serwer, G. A., LeRoy, S., & Armstrong, B.
Venue
Circulation
Published
1991-12
Volume
84
Issue
6
Pages
2318-2324
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W1971712633
Cited by
125
References
0
FWCI
8.50
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Use of radiofrequency current to ablate accessory connections in children. https://app.cochat.ai/papers/10.1161/01.cir.84.6.2318
The paper
Dick, M., O'Connor, B. K., Serwer, G. A., LeRoy, S., & Armstrong, B. (1991). Use of radiofrequency current to ablate accessory connections in children. Circulation. https://doi.org/10.1161/01.cir.84.6.2318

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.