The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Radiation exposure during radiofrequency catheter ablation of accessory atrioventricular connections.
Open accessAbstract
BACKGROUND: Catheter ablation of accessory atrioventricular (AV) connections has been demonstrated to be effective in more than 85% of patients. One of the risks of this procedure is radiation exposure during the fluoroscopic imaging necessary to guide catheter manipulation. The objective of the present study was to measure the radiation received by patients and physicians during radiofrequency catheter ablation and to estimate the resultant somatic and genetic risks. METHODS AND RESULTS: Radiation exposure to patients and physicians was measured during attempts at radiofrequency catheter ablation of accessory AV connections in 31 consecutive patients. Radiation exposure was measured using thermoluminescent sensors placed on the patient and on the physician. Somatic and genetic risks were estimated based on the radiation levels recorded using these sensors. The durations of fluoroscopy and of the catheter ablation procedure were recorded for each patient. Catheter ablation was successful in 28 of 31 patients (90%). Mean +/- SD duration of fluoroscopy was 44 +/- 40 minutes. The largest patient radiation dose was measured over the ninth vertebral body posteriorly (median, 7.26 rem [roentgen equivalents man]; range, 0.31-135.7 rem). Median radiation dose to the thyroid was 0.46 rem (range, 0.06-7.26 rem), and median radiation dose to the posterior iliac crest was 2.43 rem (range, 0.01-8.3 rem). The greatest radiation dose to the operator was recorded at the left hand (99 mrem). Mean radiation dose to the operator's eyes was 28 mrem. CONCLUSIONS: Radiofrequency catheter ablation of accessory AV connections may result in significant radiation exposure to the patient and to the physician. Each hour of fluoroscopic imaging is associated with a lifetime risk of developing a fatal malignancy of 0.1% and a risk of a genetic defect of 20 per 1 million births. Although these risks must be recognized, they are relatively small compared with the risks associated with alternate approaches to management, including no therapy, antiarrhythmic drug therapy, and surgery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jackman, W. M., Wang, X., Friday, K. J., Roman, C. A., Moulton, K. P., Beckman, K. J., McClelland, J. H., Twidale, N., Hazlitt, H. A., Prior, M. I., et al. (1991) · New England Journal of Medicine · doi:10.1056/nejm199106063242301 · Cited by 1,422
Cited by
Calkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.05.012 · Cited by 2,755
Self-citationCalkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Europace · doi:10.1093/europace/eus027 · Cited by 2,722
Self-citationCalkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Heart Rhythm · doi:10.1016/j.hrthm.2011.12.016 · Cited by 1,456
Self-citationRadiofrequency Catheter Ablation for Tachyarrhythmias in Children and Adolescents
Kugler, J. D., Danford, D. A., Deal, B. J., Gillette, P. C., Perry, J. C., Silka, M. J., Van Hare, G. F., & Walsh, E. P. (1994) · New England Journal of Medicine · doi:10.1056/nejm199405263302103 · Cited by 384
Kirchhof, P., Auricchio, A., Bax, J., Crijns, H., Camm, J., Diener, H.-C., Goette, A., Hindricks, G., Hohnloser, S., Kappenberger, L., et al. (2007) · Europace · doi:10.1093/europace/eum191 · Cited by 293
Metadata
- Authors
- Calkins, H., Niklason, L., Sousa, J., el-Atassi, R., Langberg, J., & Morady, F.
- Venue
- Circulation
- Published
- 1991-12
- Volume
- 84
- Issue
- 6
- Pages
- 2376-2382
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2072273815
- Cited by
- 238
- References
- 1
- FWCI
- 17.48
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Radiation exposure during radiofrequency catheter ablation of accessory atrioventricular connections. https://app.cochat.ai/papers/10.1161/01.cir.84.6.2376
- The paper
- Calkins, H., Niklason, L., Sousa, J., el-Atassi, R., Langberg, J., & Morady, F. (1991). Radiation exposure during radiofrequency catheter ablation of accessory atrioventricular connections. Circulation. https://doi.org/10.1161/01.cir.84.6.2376
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.