The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Radiofrequency catheter ablation of accessory atrioventricular connections in 250 patients. Abbreviated therapeutic approach to Wolff-Parkinson-White syndrome.
Abstract
BACKGROUND: The purpose of this study was to report the results and complications of radiofrequency catheter ablation of accessory atrioventricular (AV) connections by using an abbreviated approach aimed at minimizing the duration of the procedure. METHODS AND RESULTS: Two hundred fifty consecutive patients with the Wolff-Parkinson-White syndrome or paroxysmal supraventricular tachycardia involving a concealed accessory AV connection underwent catheter ablation with the use of radiofrequency current. In 179 of the 250 patients, catheter ablation was performed at the time of an initial electrophysiology test. Two hundred thirty-five patients had one accessory AV connection and 15 patients had two or more. One hundred eighty-three accessory AV connections were manifest and 84 were concealed. One hundred sixty-one were were located in the free wall of the left ventricle, 47 were in the right free wall, 44 were posteroseptal, 10 were anteroseptal, and five were intermediate test, and the ablation procedure was recorded for each patient, as was the total duration of fluoroscopy. A follow-up electrophysiology test was performed 2-3 months after the ablation procedure. Ninety-four percent of patients had all accessory AV connections successfully ablated and remained free of symptomatic tachycardia during a mean follow-up of 10 +/- 4 months. Two hundred nineteen patients (88%) had all accessory AV connections ablated during the initial attempt at catheter ablation. Mean duration of the entire procedure was 134 +/- 75 minutes. Procedure duration was longest in patients with multiple accessory AV connections, shortest in patients with intermediate septal accessory AV connections, and similar in all other locations. A nonfatal complication occurred in nine patients (4%). CONCLUSIONS: The results of this study indicate that catheter ablation of accessory AV connections with radiofrequency current can be performed safely and expeditiously in a majority of patients and confirm in a large series the feasibility of catheter ablation at the time of an initial diagnostic electrophysiology test. This abbreviated therapeutic approach avoids the need for electropharmacological testing, long-term antiarrhythmic drug therapy, and surgical therapy in the majority of patients with the Wolff-Parkinson-White syndrome or with symptomatic tachycardias involving accessory AV connections.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jackman, W. M., Wang, X., Friday, K. J., Roman, C. A., Moulton, K. P., Beckman, K. J., McClelland, J. H., Twidale, N., Hazlitt, H. A., Prior, M. I., et al. (1991) · New England Journal of Medicine · doi:10.1056/nejm199106063242301 · Cited by 1,422
Ventricular fibrillation in the Wolff-Parkinson-White syndrome
Klein, G. J., Bashore, T. M., Sellers, T. D., Pritchett, E. L. C., Smith, W. M., & Gallagher, J. J. (1979) · New England Journal of Medicine · doi:10.1056/nejm197911153012003 · Cited by 830
Cited by
Zipes, D. P., Camm, A. J., Borggrefe, M., Buxton, A. E., Chaitman, B., Fromer, M., Gregoratos, G., Klein, G., Moss, A. J., Myerburg, R. J., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.178233 · Cited by 1,080
Blomstrom-Lundqvist (2003) · doi:10.1161/01.cir.0000091380.04100.84 · Cited by 955
2023 ACC/AHA/ACCP/HRS Guideline for the Diagnosis and Management of Atrial Fibrillation
Joglar, J. A., Chung, M. K., Armbruster, A. L., Benjamin, E. J., Chyou, J. Y., Cronin, E. M., Deswal, A., Eckhardt, L. L., Goldberger, Z. D., Gopinathannair, R., et al. (2024) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2023.08.017 · Cited by 933
Calkins, H., Yong, P., Miller, J. M., Olshansky, B., Carlson, M., Saul, J. P., Huang, S. K. S., Liem, L. B., Klein, L. S., Moser, S. A., et al. (1999) · Circulation · doi:10.1161/01.cir.99.2.262 · Cited by 611
Self-citationPage, R. L., Joglar, J. A., Caldwell, M. A., Calkins, H., Conti, J. B., Deal, B. J., Estes, N. A. M., Field, M. E., Goldberger, Z. D., Hammill, S. C., et al. (2016) · Circulation · doi:10.1161/cir.0000000000000311 · Cited by 595
Self-citation2015 ACC/AHA/HRS Guideline for the Management of Adult Patients With Supraventricular Tachycardia
Page, R. L., Joglar, J. A., Caldwell, M. A., Calkins, H., Conti, J. B., Deal, B. J., Estes, N. A. M., Field, M. E., Goldberger, Z. D., Hammill, S. C., et al. (2016) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2015.08.856 · Cited by 439
Self-citationBubien, R. S., Knotts-Dolson, S. M., Plumb, V. J., & Kay, G. N. (1996) · Circulation · doi:10.1161/01.cir.94.7.1585 · Cited by 284
Epstein, A. E., Miles, W. M., Benditt, D. G., Camm, A. J., Darling, E. J., Friedman, P. L., Garson, A., Harvey, J. C., Kidwell, G. A., Klein, G. J., et al. (1996) · Circulation · doi:10.1161/01.cir.94.5.1147 · Cited by 220
Brugada, P., Andries, E., Gürsoy, S., & Brugada, J. (1993) · The Lancet · doi:10.1016/0140-6736(93)91155-f · Cited by 71
Metadata
- Authors
- Calkins, H., Langberg, J., Sousa, J., el-Atassi, R., Leon, A., Kou, W., Kalbfleisch, S., & Morady, F.
- Venue
- Circulation
- Published
- 1992-04
- Volume
- 85
- Issue
- 4
- Pages
- 1337-1346
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W1974322761
- Cited by
- 399
- References
- 2
- FWCI
- 32.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.