Intravascular ultrasound imaging of coronary arteries. Is three layers the norm?
Abstract
BACKGROUND: The purpose of this study was to evaluate the significance of the three-layered appearance of coronary arteries in adolescence and adults from intravascular ultrasound scans and to correlate these observations with histopathology. METHODS AND RESULTS: Sixteen intact hearts were excised at autopsy from patients with no clinical history of coronary artery disease. The patients' ages ranged from 13 to 55 years. A 30-MHz ultrasound imaging catheter was used to obtain images throughout the epicardial coronary vasculature. A total of 72 image cross sections was marked by epivascular sutures, and the corresponding histological sections were examined. Ultrasound images were classified into two groups: images exhibiting three-layered appearance and images without distinct layering. Histological analysis revealed a significantly greater degree of intimal thickening in segments with three layers (243 +/- 105 microns) than in nonlayered segments (112 +/- 55 microns). Discriminant analysis of these data predicted the threshold between the two groups to be 178 microns. Measurements of medial thickness were not different between these two groups (235 +/- 61 versus 210 +/- 76 microns). In the nonlayered group, the average patient age was 27.1 +/- 8.5 years, whereas in the three-layered groups, the average age was 42.8 +/- 9.8 years. CONCLUSIONS: The intracoronary ultrasound image appearance of young, morphologically normal coronary artery walls is homogeneous without layering. A three-layered appearance suggests the presence of at least 178 microns of intimal thickening and is seen more frequently with advancing age.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Mintz, G. S., Nissen, S. E., Anderson, W. D., Bailey, S. R., Erbel, R., Fitzgerald, P. J., Pinto, F. J., Rosenfield, K., Siegel, R. J., Tuzcu, E. M., et al. (2001) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(01)01175-5 · Cited by 2,185
Self-citationJang, I.-K., Bouma, B. E., Kang, D.-H., Park, S.-J., Park, S.-W., Seung, K.-B., Choi, K.-B., Shishkov, M., Schlendorf, K., Pomerantsev, E., et al. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(01)01799-5 · Cited by 1,000
Intravascular Ultrasound: Novel Pathophysiological Insights and Current Clinical Applications
Nissen, S. E., & Yock, P. (2001) · Circulation · doi:10.1161/01.cir.103.4.604 · Cited by 840
Self-citationTuzcu, E. M., Kapadia, S. R., Tutar, E., Ziada, K. M., Hobbs, R. E., McCarthy, P. M., Young, J. B., & Nissen, S. E. (2001) · Circulation · doi:10.1161/01.cir.103.22.2705 · Cited by 678
Assessment of Coronary Arterial Plaque by Optical Coherence Tomography
Kume, T., Akasaka, T., Kawamoto, T., Watanabe, N., Toyota, E., Neishi, Y., Sukmawan, R., Sadahira, Y., & Yoshida, K. (2006) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2005.11.035 · Cited by 573
Accuracy of In Vivo Coronary Plaque Morphology Assessment
Nasu, K., Tsuchikane, E., Katoh, O., Vince, D. G., Virmani, R., Surmely, J.-F., Murata, A., Takeda, Y., Ito, T., Ehara, M., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.02.044 · Cited by 496
Yamagishi, M., Terashima, M., Awano, K., Kijima, M., Nakatani, S., Daikoku, S., Ito, K., Yasumura, Y., & Miyatake, K. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00533-1 · Cited by 435
Hodgson, J. M., Reddy, K. G., Suneja, R., Nair, R. N., Lesnefsky, E. J., & Sheehan, H. M. (1993) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(93)90714-c · Cited by 359
Percutaneous insertion of the pulmonary valve
Bonhoeffer, P., Boudjemline, Y., Qureshi, S. A., Le Bidois, J., Iserin, L., Acar, P., Merckx, J., Kachaner, J., & Sidi, D. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)01822-3 · Cited by 307
Dearani, J. A., Danielson, G. K., Puga, F. J., Schaff, H. V., Warnes, C. W., Driscoll, D. J., Schleck, C. D., & Ilstrup, D. M. (2003) · The Annals of Thoracic Surgery · doi:10.1016/s0003-4975(02)04547-2 · Cited by 277
Potena, L., Grigioni, F., Magnani, G., Ortolani, P., Coccolo, F., Sassi, S., Koessels, K., Marrozzini, C., Marzocchi, A., Carigi, S., et al. (2005) · American Journal of Transplantation · doi:10.1111/j.1600-6143.2005.01015.x · Cited by 19
Metadata
- Authors
- Fitzgerald, P. J., St Goar, F. G., Connolly, A. J., Pinto, F. J., Billingham, M. E., Popp, R. L., & Yock, P. G.
- Venue
- Circulation
- Published
- 1992-07
- Volume
- 86
- Issue
- 1
- Pages
- 154-158
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W1997238760
- Cited by
- 244
- References
- 0
- FWCI
- 27.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.