CoChat

Abnormal left ventricular intracavitary flow acceleration in patients undergoing aortic valve replacement for aortic stenosis. A marker for high postoperative morbidity and mortality.

Aurigemma, G, Battista, S, Orsinelli, D, Sweeney, A, Pape, L, Cuénoud, H · 1992 · Circulation
Cited by 144

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

BACKGROUND: We examined the clinical and echocardiographic characteristics of patients undergoing aortic valve replacement for aortic stenosis whose continuous wave Doppler studies showed abnormal intracavitary flow acceleration. METHODS AND RESULTS: The clinical and Doppler echocardiographic records of 53 consecutive patients undergoing aortic valve replacement for aortic stenosis were reviewed. Doppler echocardiography was performed at a mean of 6.6 days (range, 0-22 days) after surgery. Thirteen patients (group 1) had a dagger-shaped high-velocity systolic flow signal indicative of abnormal intracavitary flow acceleration on their postoperative Doppler study; group 2 comprised 40 aortic stenosis patients who underwent aortic valve replacement but had no postoperative evidence of abnormal intracavitary flow acceleration. Group 1 postoperative abnormal intracavitary flow velocities ranged from 1.8 to 6.8 m/sec (mean, 4.9 +/- 0.9 m/sec): Resulting dynamic gradients ranged from 10 to 184 mm Hg (mean, 104.6 +/- 32 mm Hg). Compared with group 2, group 1 patients had a distinctive ventricular geometry with more-pronounced hypertrophy, smaller cavities, and higher ejection fraction. Systolic anterior motion of the mitral valve did not accompany abnormal intracavitary flow acceleration in any patient. Six of 13 group 1 patients suffered postoperative hemodynamic compromise characterized by severe hypotension despite adequate pulmonary capillary wedge pressures; group 1 postoperative mortality was significantly greater than that seen in group 2 patients (38% versus 12%, p less than 0.05). CONCLUSIONS: Abnormal intracavitary flow acceleration after aortic valve replacement for severe aortic stenosis is associated with a distinctive ventricular geometry and supernormal systolic function but not systolic anterior motion of the mitral valve. Such flow acceleration appears to be a marker for increased postoperative morbidity and mortality. Preoperative and postoperative Doppler echocardiography may be useful in risk stratification and guiding therapy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.86.3.926

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 144

Metadata

Authors
Aurigemma, G., Battista, S., Orsinelli, D., Sweeney, A., Pape, L., & Cuénoud, H.
Venue
Circulation
Published
1992-09
Volume
86
Issue
3
Pages
926-936
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2003656977
Cited by
144
References
1
FWCI
2.71
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Abnormal left ventricular intracavitary flow acceleration in patients undergoing aortic valve replacement for aortic stenosis. A marker for high postoperative morbidity and mortality. https://app.cochat.ai/papers/10.1161/01.cir.86.3.926
The paper
Aurigemma, G., Battista, S., Orsinelli, D., Sweeney, A., Pape, L., & Cuénoud, H. (1992). Abnormal left ventricular intracavitary flow acceleration in patients undergoing aortic valve replacement for aortic stenosis. A marker for high postoperative morbidity and mortality. Circulation. https://doi.org/10.1161/01.cir.86.3.926

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.