Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 168

The DOI matches its Crossref record.

New findings concerning ventricular septation in the human heart. Implications for maldevelopment.

Lamers, W H, Wessels, A, Verbeek, F J, Moorman, A F, Virágh, S, Wenink, A C, Gittenberger-de Groot, A C, Anderson, R H·1992·Circulation

Abstract

BACKGROUND: The mechanics involved in development of the inlet component of the morphologically right ventricle are, as yet, undecided. Some argue that this component is derived from the descending limb of the ventricular loop, and that the inlet and apical trabecular components of the muscular ventricular septum have separate developmental origins. Others state that the entirety of the right ventricle grows from the ascending limb of the loop, and that the muscular septum, apart from its outer component, has a unitary origin. We now have material from human embryos at our disposal, which, we believe, solves this conundrum. METHODS AND RESULTS: We used a monoclonal antibody against an antigen to neural tissue from the chick to demarcate a ring of cells separating the descending (inlet) and ascending (outlet) limbs of the developing ventricular loop of the human heart. Preparation of serial sections of graded human embryos enabled us to trace the fate of this ring, and hence the formation of the inlet of the right ventricle, to the completion of cardiac septation. Eight embryos were studied, encompassing stages 14-23 of the Carnegie classification. The ring of cells initially separating the ascending and descending limbs of the ventricular loop were, at the conclusion of ventricular septation, located within the atrioventricular junction, sequestrated for the most part in the terminal segment of atrial myocardium. CONCLUSIONS: Our study conclusively shows that the inlet component of the morphologically right ventricle is derived from the ascending limb of the embryonic ventricular loop, and that the inlet and apical trabecular components of the muscular septum are derived from the same primary ventricular septum.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.86.4.1194

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 168

Metadata

Authors
Lamers, W. H., Wessels, A., Verbeek, F. J., Moorman, A. F., Virágh, S., Wenink, A. C., Gittenberger-de Groot, A. C., & Anderson, R. H.
Venue
Circulation
Published
1992-10
Volume
86
Issue
4
Pages
1194-1205
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2030477506
Cited by
168
References
0
FWCI
1.53
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: New findings concerning ventricular septation in the human heart. Implications for maldevelopment. https://app.cochat.ai/papers/10.1161/01.cir.86.4.1194
The paper
Lamers, W. H., Wessels, A., Verbeek, F. J., Moorman, A. F., Virágh, S., Wenink, A. C., Gittenberger-de Groot, A. C., & Anderson, R. H. (1992). New findings concerning ventricular septation in the human heart. Implications for maldevelopment. Circulation. https://doi.org/10.1161/01.cir.86.4.1194

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.