Temperature monitoring during radiofrequency catheter ablation of accessory pathways.

Open access
Langberg, J J, Calkins, H, el-Atassi, R, Borganelli, M, Leon, A, Kalbfleisch, S J, Morady, F · 1992 · Circulation

Abstract

BACKGROUND: Animal studies have suggested that the temperature of the electrode-tissue interface during radiofrequency catheter ablation accurately predicts lesion size. The purpose of the current study was to evaluate the utility of continuous temperature monitoring during radiofrequency catheter ablation in patients with Wolff-Parkinson-White syndrome. METHODS AND RESULTS: Twenty patients with manifest preexcitation were included in the study. The ablation catheter was positioned on the ventricular side of the mitral annulus for left-sided accessory pathways and on the atrial side of the tricuspid annulus for right-sided and septal accessory pathways. A thermistor imbedded in the distal electrode of the ablation catheter allowed continuous temperature monitoring during each energy application. To define the relation between power and temperature, radiofrequency current was applied several times at each site using outputs of 20, 30, 40, and 50 W. The accessory pathways were successfully ablated in each of the 20 patients. Because of marked variability in the efficiency of heating between sites, power output did not predict temperature. However, at any given site, there was a positive dose-response relation between power and temperature. Radiofrequency energy applications on the atrial side of the tricuspid annulus produced lower temperatures than did applications on the ventricular side of the mitral annulus (49 +/- 7 versus 60 +/- 16 degrees C, p = 0.0001). Transient block in the accessory pathways occurred at a mean of 50 +/- 8 degrees C, whereas permanent block was seen at a mean of 62 +/- 15 degrees C (p = 0.0001). Less than half of the applications at outputs < or = 40 W produced temperatures adequate to interrupt accessory pathway conduction. An abrupt rise in impedance caused by coagulum formation occurred only at temperatures between 95 and 100 degrees C. CONCLUSIONS: Temperature monitoring may facilitate radiofrequency catheter ablation of accessory pathways. By adjusting power output to ensure that adequate but not excessive temperatures have been achieved, a rise in impedance can be avoided and the total number of energy applications and procedure duration may be reduced.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.86.5.1469

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 179

Metadata

Authors
Langberg, J. J., Calkins, H., el-Atassi, R., Borganelli, M., Leon, A., Kalbfleisch, S. J., & Morady, F.
Venue
Circulation
Published
1992-11
Volume
86
Issue
5
Pages
1469-1474
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2016212780
Cited by
179
References
0
FWCI
12.88
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Temperature monitoring during radiofrequency catheter ablation of accessory pathways. https://app.cochat.ai/papers/10.1161/01.cir.86.5.1469
The paper
Langberg, J. J., Calkins, H., el-Atassi, R., Borganelli, M., Leon, A., Kalbfleisch, S. J., & Morady, F. (1992). Temperature monitoring during radiofrequency catheter ablation of accessory pathways. Circulation. https://doi.org/10.1161/01.cir.86.5.1469

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.