Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 259

The DOI matches its Crossref record.

Frequency domain measures of heart rate variability before the onset of nonsustained and sustained ventricular tachycardia in patients with coronary artery disease.

Huikuri, H V, Valkama, J O, Airaksinen, K E, Seppänen, T, Kessler, K M, Takkunen, J T, Myerburg, R J · 1993 · Circulation

Abstract

BACKGROUND: Low heart rate variability (HRV) is associated with an increased risk of arrhythmic death and ventricular tachycardia (VT). The purpose of this study was to examine whether there is a temporal relation between changes in HRV and the onset of spontaneous episodes of VT in patients at high risk of life-threatening arrhythmias. METHODS AND RESULTS: Components of HRV in the frequency domain were analyzed before the onset of 28 episodes of nonsustained VT (more than four impulses; duration < 30 seconds) and 12 episodes of sustained VT (> 30 seconds or requiring defibrillation) in 18 patients with coronary artery disease. Seven patients had survived cardiac arrest not associated with acute myocardial infarction, and 11 had a history of sustained VT. All frequency domain measures of HRV, i.e., total power (p < 0.001), high-frequency power (p < 0.05), low-frequency power (p < 0.01), very-low-frequency power (p < 0.01), and ultralow-frequency power (p < 0.05), were significantly lower before the onset of sustained VT than before nonsustained VT. Total power of HRV was also lower during the 1-hour period before the onset of sustained VT than the average 24-hour HRV (p < 0.05). An indirect correlation existed between the length of VT and the total power of HRV analyzed during the 15 minutes before the onset of VT (r = 0.54, p < 0.01). HRV had a trend toward increasing values before the onset of nonsustained VT (p < 0.01) but not before the sustained VT episodes. The ratio between low-frequency and high-frequency powers increased substantially before both nonsustained and sustained VT episodes (p = 0.06 and p = 0.05, respectively). The rate of VT or the coupling interval initiating the VT did not differ significantly between the nonsustained and sustained VT. CONCLUSIONS: Spontaneous episodes of VT are preceded by changes in HRV in the frequency domain. Divergent dynamics of HRV before the onset of nonsustained and sustained VT episodes may reflect differences in factors that can facilitate the perpetuation of these arrhythmias.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.87.4.1220

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 259

Metadata

Authors
Huikuri, H. V., Valkama, J. O., Airaksinen, K. E., Seppänen, T., Kessler, K. M., Takkunen, J. T., & Myerburg, R. J.
Venue
Circulation
Published
1993-04
Volume
87
Issue
4
Pages
1220-1228
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2095745637
Cited by
259
References
0
FWCI
14.31
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Frequency domain measures of heart rate variability before the onset of nonsustained and sustained ventricular tachycardia in patients with coronary artery disease. https://app.cochat.ai/papers/10.1161/01.cir.87.4.1220
The paper
Huikuri, H. V., Valkama, J. O., Airaksinen, K. E., Seppänen, T., Kessler, K. M., Takkunen, J. T., & Myerburg, R. J. (1993). Frequency domain measures of heart rate variability before the onset of nonsustained and sustained ventricular tachycardia in patients with coronary artery disease. Circulation. https://doi.org/10.1161/01.cir.87.4.1220

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.