CoChat

Noninvasive measurement of rate of left ventricular relaxation by Doppler echocardiography. Validation with simultaneous cardiac catheterization.

Open access
Nishimura, R A, Schwartz, R S, Tajik, A J, Holmes, D R · 1993 · Circulation
Cited by 99

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

BACKGROUND: The instantaneous pressure gradient between the left ventricle and left atrium during systole can be calculated from the mitral regurgitation Doppler velocity curve. The purpose of our study was to determine the accuracy of measuring the time constant of relaxation (TAU) derived from the Doppler mitral regurgitation signal by comparing it with simultaneous high-fidelity left ventricular pressure measurements in humans. METHODS AND RESULTS: Twenty-five patients had continuous-wave Doppler mitral regurgitation recordings performed with simultaneous high-fidelity left ventricular pressure measurements. Fifteen of these patients had measurements of six to eight beats at various RR intervals. Doppler velocity curves were converted to left ventricular pressure curves by different methods through application of the modified Bernoulli equation at 3-msec intervals. The correlation between catheter-derived and Doppler-derived TAU was best when a zero asymptote and knowledge of the left ventricular end-diastolic pressure were used. A less optimal but acceptable method used the addition of 20 mm Hg to the Doppler-derived ventriculoatrial gradient. Use of a nonzero asymptote for calculation of TAU yielded poor correlation between catheter and Doppler measurements. The correlation of percentage change in Doppler-derived TAU plotted against percentage change in catheter-derived TAU was poor. CONCLUSIONS: The descending limb of the Doppler-derived mitral regurgitation velocity signal can be used as a semiquantitative estimate of the rate of ventricular relaxation. This method requires knowledge of left atrial pressure and may not be sufficiently accurate for detecting small changes in the rate of relaxation on a beat-to-beat basis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.88.1.146

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 99

Metadata

Authors
Nishimura, R. A., Schwartz, R. S., Tajik, A. J., & Holmes, D. R.
Venue
Circulation
Published
1993-07
Volume
88
Issue
1
Pages
146-155
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2029984926
Cited by
99
References
1
FWCI
4.67
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Noninvasive measurement of rate of left ventricular relaxation by Doppler echocardiography. Validation with simultaneous cardiac catheterization. https://app.cochat.ai/papers/10.1161/01.cir.88.1.146
The paper
Nishimura, R. A., Schwartz, R. S., Tajik, A. J., & Holmes, D. R. (1993). Noninvasive measurement of rate of left ventricular relaxation by Doppler echocardiography. Validation with simultaneous cardiac catheterization. Circulation. https://doi.org/10.1161/01.cir.88.1.146

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.