Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 197

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Echocardiographic follow-up of atrial septal defect after catheter closure by double-umbrella device.

Boutin, C, Musewe, N N, Smallhorn, J F, Dyck, J D, Kobayashi, T, Benson, L N · 1993 · Circulation

Abstract

BACKGROUND: Transcatheter device occlusion of atrial septal defects is an attractive approach, but its efficacy and place in patient management remain to be determined. METHODS AND RESULTS: To evaluate the medium-term results of atrial septal defect device occlusion and factors influencing residual shunting, transesophageal and transthoracic echocardiograms of 49 patients were reviewed. Transesophageal echocardiograms on 48 patients immediately following surgical closure revealed residual shunting in 2% compared with 91% after device occlusion; this proportion decreased to 53% after a mean follow-up of 10 months. The actuarial analysis suggests a progressive resolution of shunting with time. One patient had residual shunting by transesophageal echocardiography immediately after surgical closure compared with 29 after a mean follow-up of 10 months after device occlusion. Residual shunting was not influenced by (1) dimension, location, or position with relation to the device as assessed by transesophageal echocardiography; (2) location of the defect; or (3) device size relative to the stretched dimension of the defect. In 15 patients, a poor correlation existed between transesophageal and transthoracic echocardiographic findings. Variability in serial transthoracic echocardiographic findings was observed in 14. Right ventricular dimension, heart size, and presence of a murmur at follow-up did not correlate with the presence or size of residual shunting after device occlusion. CONCLUSIONS: These results suggest that ongoing spontaneous resolution of residual shunting occurs after device insertion. Factors related to the defect or device could not predict eventual resolution of residual shunting. Transthoracic echocardiography in the follow-up of these patients may not be reliable in determining presence of residual shunting.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.88.2.621

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 197

Metadata

Authors
Boutin, C., Musewe, N. N., Smallhorn, J. F., Dyck, J. D., Kobayashi, T., & Benson, L. N.
Venue
Circulation
Published
1993-08
Volume
88
Issue
2
Pages
621-627
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2057349741
Cited by
197
References
1
FWCI
4.61
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.