Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 165

The DOI matches its Crossref record.

Regional entrainment of atrial fibrillation studied by high-resolution mapping in open-chest dogs.

Open access
Kirchhof, C, Chorro, F, Scheffer, G J, Brugada, J, Konings, K, Zetelaki, Z, Allessie, M·1993·Circulation

Abstract

BACKGROUND: It recently has been demonstrated that during atrial fibrillation, a short and variable excitable gap exists, allowing regional control of atrial fibrillation by local stimulation. In the present study, we visualized the process of excitation during regional entrainment of atrial fibrillation by rapid pacing. METHODS AND RESULTS: In six open-chest dogs, the excitation of the left atrial free wall was mapped using a spoon-shaped mapping electrode (248 points). Episodes of atrial fibrillation were induced by burst pacing (50 Hz, 2 seconds). During atrial fibrillation, the electrograms showed rapid irregular activity with a median cycle length of 98 +/- 16 ms (mean +/- SD, n = 6). Rapid pacing in the center of the mapping electrode at intervals slightly shorter or longer than the median atrial fibrillation interval resulted in regional capture of atrial fibrillation. The window of entrainment was 16 +/- 5 ms. Mapping of atrial fibrillation showed that the left atrium was activated by fibrillatory wavelets coming from different directions. During entrainment, a relatively large area with a diameter of about 4 cm was activated by uniform wave fronts propagating away from the site of stimulation. The area of entrainment was limited by intra-atrial conduction block and by collision with fibrillation waves. Regional control of atrial fibrillation was lost by pacing either too slowly or too rapidly. In the first case, retrograde invasion of the area of entrainment by fibrillatory waves resulted in depolarization of the pacing site prior to the stimulus. Pacing too rapidly caused acceleration of atrial fibrillation by induction of local intra-atrial reentry circuits with a revolution time shorter than the pacing interval. CONCLUSIONS: During atrial fibrillation, an area with a diameter of about 4 cm can be entrained by local pacing. The resulting reduction in fibrillating tissue mass was not sufficient to terminate atrial fibrillation. Extension of the area of entrainment was limited by intra-atrial conduction block, whereas entrainment at a too high rate resulted in acceleration of atrial fibrillation by induction of local microreentry.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.88.2.736

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 165

Metadata

Authors
Kirchhof, C., Chorro, F., Scheffer, G. J., Brugada, J., Konings, K., Zetelaki, Z., & Allessie, M.
Venue
Circulation
Published
1993-08
Volume
88
Issue
2
Pages
736-749
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2064419632
Cited by
165
References
0
FWCI
7.47
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Regional entrainment of atrial fibrillation studied by high-resolution mapping in open-chest dogs. https://app.cochat.ai/papers/10.1161/01.cir.88.2.736
The paper
Kirchhof, C., Chorro, F., Scheffer, G. J., Brugada, J., Konings, K., Zetelaki, Z., & Allessie, M. (1993). Regional entrainment of atrial fibrillation studied by high-resolution mapping in open-chest dogs. Circulation. https://doi.org/10.1161/01.cir.88.2.736

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.