The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Vascular complications after balloon and new device angioplasty.
Open accessAbstract
BACKGROUND: Despite their potential advantages, new coronary angioplasty devices may be associated with more frequent vascular complications than noted after standard balloon angioplasty, theoretically due to the larger sheaths and prolonged periods of anticoagulation required by some of these devices. This study sought to identify the incidence, predictors, and clinical outcome of vascular complications after new device angioplasty. METHODS AND RESULTS: The clinical course of 1413 patients was reviewed after balloon or new device angioplasty. Vascular complications were defined as formation of a pseudoaneurysm, arteriovenous fistula, retroperitoneal hematoma, or groin hematoma associated with a > 15-point hematocrit drop or the need for surgical repair. Stepwise logistic regression was used to identify independent predictors for vascular complications. Vascular complications developed after 84 (5.9%) procedures; they occurred more frequently after intracoronary stenting (14.0%) and extraction atherectomy (12.5%) than after balloon angioplasty (3.2%) (odds ratios, 4.86; P < .001, and 4.26, P < .05, respectively). Independent predictors of vascular complications included the use of intraprocedural thrombolytic agents (P < .01), intracoronary stenting (P < .005), or extraction atherectomy (P < .05); high maximum creatinine level (P < .005); low nadir platelet count (P < .001); longer periods of excess anticoagulation (P < .05); and the need for repeat coronary angioplasty (P < .005). Vascular complications were not related to the size of the arterial sheath used. CONCLUSIONS: Vascular complications developed more frequently after new device angioplasty than after balloon angioplasty, with the risk for vascular complications directly related to the degree of periprocedural anticoagulation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1990) · Choice Reviews Online · doi:10.5860/choice.27-3338 · Cited by 35,305
Best Subsets Logistic Regression
Hosmer, D. W., Jovanovic, B., & Lemeshow, S. (1989) · Biometrics · doi:10.2307/2531779 · Cited by 1,176
Kresowik, T. F., Khoury, M. D., Miller, B. V., Winniford, M. D., Shamma, A. R., Sharp, W. J., Blecha, M. B., & Corson, J. D. (1991) · Journal of Vascular Surgery · doi:10.1016/0741-5214(91)90226-k · Cited by 351
Helvie, M. A., Rubin, J., Silver, T., & Kresowik, T. F. (1988) · American Journal of Roentgenology · doi:10.2214/ajr.150.5.1177 · Cited by 78
Cited by
Biodegradable nanoparticles for drug and gene delivery to cells and tissue
Panyam, J., & Labhasetwar, V. (2003) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(02)00228-4 · Cited by 3,361
WRITING COMMITTEE MEMBERS, Smith, S. C., Feldman, T. E., Hirshfeld, J. W., Jacobs, A. K., Kern, M. J., King, S. B., Morrison, D. A., O’Neill, W. W., Schaff, H. V., et al. (2006) · Circulation · doi:10.1161/circulationaha.105.170815 · Cited by 2,218
Kiemeneij, F., Laarman, G. J., Odekerken, D., Slagboom, T., & van der Wieken, R. (1997) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(97)00064-8 · Cited by 957
Inappropriate use of bivariable analysis to screen risk factors for use in multivariable analysis
Sun, G.-W., Shook, T. L., & Kay, G. L. (1996) · Journal of Clinical Epidemiology · doi:10.1016/0895-4356(96)00025-x · Cited by 933
Moscucci, M. (2003) · European Heart Journal · doi:10.1016/s0195-668x(03)00485-8 · Cited by 918
Metadata
- Authors
- Popma, J. J., Satler, L. F., Pichard, A. D., Kent, K. M., Campbell, A., Chuang, Y. C., Clark, C., Merritt, A. J., Bucher, T. A., & Leon, M. B.
- Venue
- Circulation
- Published
- 1993-10
- Volume
- 88
- Issue
- 4
- Pages
- 1569-1578
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2076100790
- Cited by
- 268
- References
- 4
- FWCI
- 14.60
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.