Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 201

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Dependence of Gorlin formula and continuity equation valve areas on transvalvular volume flow rate in valvular aortic stenosis.

Open access
Burwash, I G, Thomas, D D, Sadahiro, M, Pearlman, A S, Verrier, E D, Thomas, R, Kraft, C D, Otto, C M·1994·Circulation

Abstract

BACKGROUND: Valve areas derived by the Gorlin formula have been observed to vary with transvalvular volume flow rate. Continuity equation valve areas calculated from Doppler-echo data have become a widely used alternate index of stenosis severity, but it is unclear whether continuity equation valve areas also vary with volume flow rate. This study was designed to investigate the effects of changing transvalvular volume flow rate on aortic valve areas calculated using both the Gorlin formula and the continuity equation in a model of chronic valvular aortic stenosis. METHODS AND RESULTS: Using a canine model of chronic valvular aortic stenosis in which anatomy and hemodynamics are similar to those of degenerative aortic stenosis, each subject (n = 8) underwent three studies at 2-week intervals. In each study, transvalvular volume flow rates were altered with saline or dobutamine infusion (mean, 10.3 +/- 5.1 flow rates per study). Simultaneous measurements were made of hemodynamics using micromanometer-tipped catheters, of ascending aortic instantaneous volume flow rate using a transit-time flowmeter, and of left ventricular outflow and aortic jet velocity curves using Doppler echocardiography. Valve areas were calculated from the invasive data by the Gorlin equation and from the Doppler-echo data by the continuity equation. In the 24 studies, mean transit-time transvalvular volume flow rate ranged from 80 +/- 33 to 153 +/- 49 mL/min (P < .0001). Comparing minimum to maximum mean volume flow rates, the Gorlin valve area changed from 0.54 +/- 0.22 cm2 to 0.68 +/- 0.21 cm2 (P < .0001), and the continuity equation valve area changed from 0.57 +/- 0.18 cm2 to 0.70 +/- 0.20 cm2 (P < .0001). A strong linear relation was observed between Gorlin valve area and mean transit-time volume flow rate for each study (median, r = .88), but the slope of this relation varied between studies. The Doppler-echo continuity equation valve area had a weaker linear relation with transit-time volume flow rate for each study (median, r = .51). CONCLUSIONS: In this model of chronic valvular aortic stenosis, both Gorlin and continuity equation valve areas were flow-dependent indices of stenosis severity and demonstrated linear relations with transvalvular volume flow rate. The changes in calculated valve area that occur with changes in transvalvular volume flow should be considered when measures of valve area are used to assess the hemodynamic severity of valvular aortic stenosis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.89.2.827

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 201

Metadata

Authors
Burwash, I. G., Thomas, D. D., Sadahiro, M., Pearlman, A. S., Verrier, E. D., Thomas, R., Kraft, C. D., & Otto, C. M.
Venue
Circulation
Published
1994-02
Volume
89
Issue
2
Pages
827-835
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2015221086
Cited by
201
References
1
FWCI
5.09
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Dependence of Gorlin formula and continuity equation valve areas on transvalvular volume flow rate in valvular aortic stenosis. https://app.cochat.ai/papers/10.1161/01.cir.89.2.827
The paper
Burwash, I. G., Thomas, D. D., Sadahiro, M., Pearlman, A. S., Verrier, E. D., Thomas, R., Kraft, C. D., & Otto, C. M. (1994). Dependence of Gorlin formula and continuity equation valve areas on transvalvular volume flow rate in valvular aortic stenosis. Circulation. https://doi.org/10.1161/01.cir.89.2.827

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.